A modern HF station is a small software crowd standing around one serial port. The transceiver exposes a single CAT (computer-aided transceiver) port, and everything wants it: WSJT-X needs it to read the frequency and key the radio, the logging program needs it to record the band and mode with each QSO, and a rig-control program needs it to drive the radio itself. Serial ports, however, are exclusive — the first program to open the port owns it, and the rest get an error. Virtual COM ports are how the crowd gets organised, and there are two distinct patterns, because there are two distinct problems.
First, name your problem: a bridge, or a crowd?
If a program needs to talk to something that speaks CAT over a serial link — an SDR program feeding a rig-control daemon, a bridge application translating between two pieces of software — the problem is a missing cable between two programs. That is the pair pattern. If several programs need the same real radio port at the same time — WSJT-X and the logger both watching the one CAT port — the problem is sharing, and that is the splitter pattern. Picking the wrong one is the usual reason virtual-port setups feel cursed.
Pattern 1: the com0com pair as a software CAT cable
A com0com pair is a null-modem cable between two applications. In station terms: a rig-control bridge — Hamlib’s rigctld daemon is the classic example of the type, serving rig control to programs that connect to it — or an SDR/control program presents a CAT-speaking serial endpoint on one end of the pair, and the program that expects to talk to a radio (WSJT-X, a logger with rig polling, a remote-control client) opens the other end and cannot tell it is not wired to hardware. The setup is the standard one from the first-pair guide:
- Create the pair and rename both ends to COM numbers (for example COM10 and COM11) with the rename procedure — radio software picks ports from lists of COM-style names and will not find CNCA0/CNCB0.
- Point the bridge or SDR-side program at one end (COM10) as its CAT serial port.
- Point WSJT-X (or the logger) at the other end (COM11), configured exactly as if a radio were attached: same baud rate and line settings the bridge expects.
- Prove it with frequency. Change the frequency on the bridge/SDR side; the program on the other end should follow. Then let WSJT-X request a band change and confirm the far side reacts. Both directions across the pair are now demonstrated.
Two honest notes about this pattern. The pair carries the CAT conversation faithfully, but it adds a software hop: if a program is picky about timing, baud-rate emulation (EmuBR, covered in the SetupG guide) makes the virtual cable behave at the set speed instead of flat-out. And the pair solves software-to-software links only — the actual radio still connects the way it always did, through its real port or USB lead, to whichever program owns that side.
Pattern 2: the splitter, when everyone wants the radio itself
When WSJT-X, the logger and the rig-control program must all watch (and occasionally drive) the radio’s one real COM port, a pair is the wrong shape — you need a hub. That is hub4com’s job, and this site covers it in the dedicated guides rather than repeating them here: Split One Serial Port Between Several Applications explains the pattern and its etiquette — a broadcast of the radio’s output to every listener is easy, while several programs transmitting commands into one port needs one-writer discipline, because two CAT commands interleaved into one stream are gibberish to the radio. The GPS half of station life works the same way: one receiver feeding mapping, logging and APRS software at once is the GPS sharing recipe, and it is the same hub, the same pattern.
Keeping the station tidy: names, notes and updates
Virtual-port setups fail socially before they fail technically: six months after installation nobody remembers which end of which pair feeds which program, and a port list full of identical names is archaeology waiting to happen. Two habits prevent it. Keep the pair ends’ names meaningful — rename pairs so the COM numbers are stable and write the mapping down (a note in the station log: COM10/COM11 = bridge to WSJT-X, hub shares COM1 to COM5/COM6). And expect Windows updates to occasionally disturb the arrangement; drivers and port assignments can need re-checking after a major update, and the symptom catalogue in the troubleshooting hub — ports gone, pairs broken — is written for exactly that morning. Five minutes of documentation when it works saves the contest weekend when it does not.
And the GPS side: position for APRS and logging
The receiver half of the station deserves one more sentence, because it is the same problem wearing a different hat: one GPS puck produces a position stream that APRS software, the logger and a mapping program may all want at once, and it is a one-way broadcast — the easiest sharing case there is. The GPS sharing recipe builds it with hub4com in three commands and is the pattern to copy. If your logging is the only consumer, a plain pair is enough: GPS-side software on one end, logger on the other. Either way, the principle from the CAT side holds — decide whether you are bridging or sharing first, and the tool choice makes itself.
The honest alternatives other hams use
com0com is the free, open-source option, not the only one, and station computers reward honesty about the trade-offs. VSP Manager, a dedicated virtual-port tool for station use, is free for licensed amateurs and is the recommendation you will meet most often in contesting circles. VSPE (Virtual Serial Ports Emulator) is the other common choice — a broader emulator whose splitter devices many SDR operators prefer. Both are named here so you can compare deliberately; this site documents the com0com route because it is free for everyone, licensed amateur or not, and because its companion hub covers the splitter pattern without extra software. If your station already runs one of the others happily, there is no prize for switching.
One expectation to set before you start: none of this makes the radio itself any less singular. There is still exactly one transmitter, and if two programs command it at cross purposes the radio will do something you did not intend — virtual ports organise access to the CAT conversation, they do not arbitrate between operators. The operator is still the arbiter; the software crowd just stops shouting over each other to reach him.
Putting it together
A typical settled station uses both patterns at once: a real radio port split by the hub so WSJT-X and the logger can both follow the frequency, and a com0com pair linking the SDR or bridge software into the same ecosystem as if it were a second radio. Everything above that sentence is patience, not money — and if the setup misbehaves, the faults are the usual ones: a program that cannot see CNC names (rename the pair), or a driver-level problem after an update, both covered from the troubleshooting hub. One practical footnote: stations that still wire a radio to the PC with a USB-to-serial CAT lead should use a decent adapter — the sponsored link lists current options: USB-to-serial adapters on Amazon (sponsored).