<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Comparisons &amp; Buying &#8211; com0com</title>
	<atom:link href="https://com0com.com/comparisons/feed/" rel="self" type="application/rss+xml" />
	<link>https://com0com.com</link>
	<description>Virtual Serial Port Driver for Windows 11/10</description>
	<lastBuildDate>Wed, 21 Oct 2026 09:42:40 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://com0com.com/wp-content/uploads/2026/04/favicon-150x150.png</url>
	<title>Comparisons &amp; Buying &#8211; com0com</title>
	<link>https://com0com.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Virtual Serial Ports on Windows Server and VMs</title>
		<link>https://com0com.com/virtual-serial-port-windows-server/</link>
					<comments>https://com0com.com/virtual-serial-port-windows-server/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 08:30:00 +0000</pubDate>
				<category><![CDATA[Comparisons & Buying]]></category>
		<guid isPermaLink="false">https://com0com.com/virtual-serial-port-windows-server/</guid>

					<description><![CDATA[Everything about virtual serial ports gets more serious on a server. The driver is the same kind of kernel code, but the machine it lands on runs other people&#8217;s workloads, answers to a change board, and enforces signing policy the way servers do — strictly, and with no patience for workarounds that a desktop user...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Everything about virtual serial ports gets more serious on a server. The driver is the same kind of kernel code, but the machine it lands on runs other people&#8217;s workloads, answers to a change board, and enforces signing policy the way servers do — strictly, and with no patience for workarounds that a desktop user might shrug at. This page is the honest server picture: what works, what absolutely should not be attempted, and the architecture that production environments actually converge on.</p>
<h2>Signing on servers: stricter ground</h2>
<p>The background every desktop guide on this site repeats applies with extra force here: com0com&#8217;s driver is test-signed, and its SourceForge signed package depends on a legacy cross-signed certificate that modern Windows accepts only in narrowing exceptions. Industry reporting through 2025 and into 2026 describes the newest releases — the Windows 11 24H2/25H2 generation and Windows Server 2025 — as removing trust in cross-signed roots by default, shrinking those exceptions further. Treat that as reported direction rather than a promise about your exact build, and test on a non-production image first; but plan on the basis that a driver strategy built on a 2012-era cross-signature has no future on server SKUs, even on machines where it happens to load today.</p>
<h2>Never test-signing on production</h2>
<p>On a personal PC, enabling Test Mode is a weighed trade-off. On a server it is simply not a proposal: <code>bcdedit -set TESTSIGNING ON</code> lowers the driver-integrity bar for the whole machine — every workload on it, not just your serial tool — demands a reboot, fights Secure Boot policy (which will often refuse it outright), and announces itself with a watermark that no audit survives gracefully. If a design document for a production server contains the words &#8220;test signing&#8221;, the correct review outcome is to send the design back. The free pair driver remains a fine citizen on desktop and lab machines (<a href="/com0com-commercial-use/">commercial use, untangled</a>); servers are a different jurisdiction.</p>
<h2>What does work on the server itself</h2>
<p>If a Windows Server genuinely needs a local virtual pair — an application and its local simulator both on the host, legacy software consolidated onto modern iron — the requirement is a <strong>properly Microsoft-signed commercial driver</strong>, chosen and licensed like any other server component, tested in the change window, and recorded in the build. That is the beginning and end of the on-host software story: signed, supported, documented. Anything less is a desktop workaround wearing a server costume.</p>
<h2>The VM angle: let the hypervisor do it</h2>
<p>Virtualisation quietly dissolves many of these requests. Most hypervisors can present a virtual COM port to a guest backed by something other than a physical UART — a named pipe, a file, or a TCP connection to another host. For the classic workloads that drive these projects (a legacy application in a VM that must &#8220;have a COM port&#8221;, a guest that needs to exchange serial-formatted data with a partner process), a hypervisor-provided port often satisfies the application without any third-party kernel driver inside the guest at all. Equally, USB and PCI passthrough can hand a guest a real serial adapter outright. The discipline is to ask, before installing anything in the guest: <em>does this need to be a driver, or just a port?</em> RDS and session-host scenarios deserve the same scepticism multiplied — per-session serial expectations on a shared host are where device servers (next section) earn their keep.</p>
<p>There is a middle path worth knowing for guests whose serial partner lives on another host entirely: bridge at the network layer rather than the driver layer. A guest can map its end of a conversation onto TCP — the com2tcp pattern from the com0com ecosystem, or the hypervisor&#8217;s own network-backed serial port — and meet a partner process, a device server, or a physical machine&#8217;s port on the far side. Framed that way, several &#8220;the VM needs a pair&#8221; requirements turn out to be &#8220;the VM needs to reach a port&#8221;, which is a networking task with networking tools, and no kernel driver is invited into the guest at all.</p>
<h2>The grown-up answer: a serial device server</h2>
<p>Production serial-over-network architecture converged years ago: the serial device lives on a dedicated box — a serial device server — attached to the network, and computers reach it over TCP. The application side then needs either a vendor redirector (a signed driver that maps a COM name to the box, maintained by the box&#8217;s manufacturer) or a protocol it can speak directly, RFC 2217 being the standard one; our <a href="/rfc2217-server-client/">RFC 2217 recipes</a> and <a href="/com2tcp-guide/">com2tcp guide</a> cover the mechanics from the free-tool side. What this buys operations is everything the in-PC driver cannot offer: no kernel code on the server, the serial hardware survives server rebuilds untouched, one device can serve whichever host needs it this quarter, and the security review is about a network appliance with a vendor, not a test-signed driver from 2012. For a single stubborn desktop-class need this is overkill; for anything a business depends on, it is simply how the job is done.</p>
<h2>The consolidation scenario, where this usually starts</h2>
<p>Most server-side virtual COM projects are born in a consolidation: a physical Windows machine from another era — running a data-collection app, an instrument controller, a serial-fed legacy service — is being virtualised or moved to a current Server release, and the migration stalls on one line in the inventory: &#8220;needs a COM port&#8221;. Work the options in the order this page has built them. First ask whether the port must be <em>in</em> the server at all: if the serial device still exists physically, a device server beside it ends the project in an afternoon and the application simply sees a network resource. If the &#8220;device&#8221; is actually another program, ask whether the two still need to share a host — pairs are an intra-machine concept, and splitting the pair across hosts converts the problem into the RFC 2217 pattern. Only if both ends genuinely live on the server does the signed-driver purchase arise, at which point it is a small, clean line in the migration budget rather than the discovery that stops the project.</p>
<h2>RDS and shared hosts: extra suspicion, same physics</h2>
<p>On a Remote Desktop Session Host, add one more layer of doubt. Serial ports — real or virtual — are machine-scoped, exclusive resources being presented to a multi-tenant session environment; which session sees which port, and what happens when two sessions want it, are questions whose answers vary by product and policy and are miserable to debug in production. The operational consensus is to keep serial off the session host: dedicate a small endpoint — a workstation, a modest dedicated box, or a device server — to the physical serial world, and let sessions consume the result over the network. It is the same conclusion as the device-server argument, reached from the multi-user direction: shared hosts and exclusive ports are natural enemies, and good architecture wins by separating them rather than mediating between them.</p>
<p>Finally, a word about documentation, because servers outlive their builders: whatever pattern you choose, write down where the serial path physically and logically runs — device, device server or hypervisor mapping, port names, and the application&#8217;s expectations — in the runbook, not in a ticket that will age out of search. Virtual COM setups fail silently years later, when a host is rebuilt without its undocumented pipe or a device server is factory-reset by a helpful hand; the runbook entry is the cheapest insurance on this entire page.</p>
<h2>Decision summary</h2>
<ul>
<li><strong>Lab, test and development servers:</strong> com0com per the normal desktop guidance, where the signed package loads; Test Mode tolerable on genuinely disposable machines.</li>
<li><strong>Production server, on-host pairs truly required:</strong> a commercially signed driver, change-managed (<a href="/com0com-vs-eltima-vspd/">the com0com vs Eltima comparison</a> is the honest version of that purchase).</li>
<li><strong>VM guests:</strong> hypervisor virtual COM (pipe/TCP-backed) or device passthrough first; guest drivers last.</li>
<li><strong>Anything shared, remote, or business-critical:</strong> serial device server on the network; retire the question permanently.</li>
</ul>
<p>The exits, for the two branches that involve buying something: <a href="/go/amazon-device-server" rel="sponsored nofollow">serial device servers on Amazon</a> (sponsored) for the hardware route, and <a href="/go/eltima-vspd" rel="sponsored nofollow">Eltima Virtual Serial Port Driver</a> (sponsored) when a signed on-host driver is genuinely the requirement. Everything else on this page was free advice, and on a server, &#8220;do not install the clever workaround&#8221; is the most valuable kind.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/virtual-serial-port-windows-server/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Can You Use com0com at Work? Commercial Use, GPLv2 and Signing</title>
		<link>https://com0com.com/com0com-commercial-use/</link>
					<comments>https://com0com.com/com0com-commercial-use/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 07:30:00 +0000</pubDate>
				<category><![CDATA[Comparisons & Buying]]></category>
		<guid isPermaLink="false">https://com0com.com/com0com-commercial-use/</guid>

					<description><![CDATA[Somewhere between &#8220;this free tool is perfect for the test bench&#8221; and an IT review, every com0com user in a company asks the same question: are we even allowed to use this at work? The question bundles three different ones — a licensing question, a security-policy question, and a support question — and they have...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Somewhere between &#8220;this free tool is perfect for the test bench&#8221; and an IT review, every com0com user in a company asks the same question: are we even allowed to use this at work? The question bundles three different ones — a licensing question, a security-policy question, and a support question — and they have three different answers. Untangled: <strong>the license is the easy part. Signing policy is the hard part. Support is the part nobody wants to say out loud.</strong></p>
<h2>The license question: GPLv2 permits commercial use</h2>
<p>com0com is released under the GNU General Public License v2. A property <em>of that license</em> — stated here as a fact about GPLv2, not as a claim the com0com project itself has made about its own product — is that running the software is unrestricted: the GPL places no field-of-use limits, so using it inside a company, on production-adjacent test rigs, in a commercial product&#8217;s development pipeline, is permitted, and no licence fee exists. The project&#8217;s SourceForge presence carries a 4.4/5 rating across 64 reviews from exactly the mixed hobbyist-and-professional crowd you&#8217;d expect.</p>
<p>The obligations in GPLv2 attach to <em>distribution</em>, not use. Keep com0com inside your organisation and nothing is triggered: install it on a hundred lab PCs and the license asks nothing of you. Redistribute it — bundle the driver into a product you ship, hand it to customers as part of a deliverable — and GPL duties arrive with it: the license text rides along, source must be available to recipients, and your own combined-work analysis needs a lawyer, not a blog post. So: this page is a plain-language orientation, <strong>not legal advice</strong>; if redistribution is your scenario, your counsel reviews it, and the review is short because GPLv2 is one of the most litigated-over and best-understood licenses in existence.</p>
<p>One bookkeeping habit makes all of this cheaper next time: whatever the outcome, file the evidence. Keep the license text, the SourceForge download source and the packages&#8217; SHA-256 checksums (published on the <a href="/download/">download page</a>) in your software inventory next to the approval. Audits do not ask whether a tool felt respectable in the meeting; they ask what was installed, from where, under which license, and the team that can answer in one email is the team whose free tools never become a finding.</p>
<h2>The real blocker #1: your signing policy</h2>
<p>None of the above gets the driver loaded. com0com&#8217;s driver is test-signed; the SourceForge signed package relies on a legacy CyberCircuits cross-signature that modern Windows honours only in narrowing exceptions. In a managed estate this plays out predictably: on some machines the signed package installs and the conversation ends; on others you meet <a href="/fix-com0com-code-52/">Code 52</a>, and the remaining free route is Test Mode.</p>
<p>Test Mode is where enterprise conversations actually die. Enabling test signing lowers the integrity bar for the entire machine — any test-signed driver, not just this one — and leaves a permanent desktop watermark announcing the fact. Security teams reject it on sight, and they are right to: a workaround that is acceptable on a hobbyist&#8217;s bench PC is a policy violation on a machine touching production data. Add the <a href="/com0com-secure-boot/">Secure Boot reality</a> — Secure Boot policy flatly blocks test signing on many builds — and the honest summary is: in a locked-down estate, com0com works exactly where the signed package happens to load, and IT cannot promise you more than that.</p>
<h2>The real blocker #2: there is no vendor</h2>
<p>com0com&#8217;s last release is 3.0.0.0, from 2012. There is no company, no support contract, no security contact, no SLA, nobody to name in your risk register under &#8220;supplier&#8221;. Procurement frameworks that happily approve GPL software still stumble here, because the question they ask is not &#8220;is it legal&#8221; but &#8220;who answers when it breaks&#8221;. For a lab tool, &#8220;the team does&#8221; is often an acceptable answer. For anything customer-facing or line-stopping, it frequently is not — and no amount of the software being excellent changes the org chart.</p>
<h2>Your three real paths</h2>
<ul>
<li><strong>Path 1 — com0com where it loads.</strong> Try the signed package on your target machines. Where it installs, you have the best free pair driver in existence, legally clean for internal use, and the project is over. Document the machine list; the ones that fail go to path 2 or 3.</li>
<li><strong>Path 2 — a commercially signed driver.</strong> Where signing policy wins, buy the signature. Eltima&#8217;s Virtual Serial Port Driver is the market&#8217;s standard answer (proper Microsoft signature, vendor support, $89.95/$199.95 as of October 2026 — see <a href="/com0com-vs-eltima-vspd/">the full comparison</a> for what the money does and does not buy): <a href="/go/eltima-vspd" rel="sponsored nofollow">Eltima Virtual Serial Port Driver</a> (sponsored). For estates, this converts an argument with the security team into a purchase order, which is why it is the common ending to this story.</li>
<li><strong>Path 3 — take serial off the PC entirely.</strong> For shared or infrastructure-grade needs, a serial device server puts the port on the network under your control, and the PC side becomes ordinary networking or a vendor redirector: <a href="/go/amazon-device-server" rel="sponsored nofollow">serial device servers on Amazon</a> (sponsored). This is the architecture industrial IT actually standardises on, and our <a href="/virtual-serial-port-windows-server/">Windows Server guide</a> explains why servers push you here.</li>
</ul>
<h2>The security review, question by question</h2>
<p>When this lands on a security team&#8217;s desk, the interrogation follows a script, and it is better to arrive with the answers written down. <strong>&#8220;Is the driver signed?&#8221;</strong> — test-signed, with a community package carrying a legacy CyberCircuits cross-signature that some Windows 11 machines accept under pre-2015 certificate exceptions and others reject with Code 52; there is no Microsoft-programme-signed build, and pretending otherwise in the ticket will be discovered at the first test. <strong>&#8220;Who maintains it, and how fast do they patch?&#8221;</strong> — nobody; the code has been final since 2012, which cuts both ways: no churn and no surprise updates, and equally no response if a vulnerability is ever identified in it. <strong>&#8220;Can we inspect it?&#8221;</strong> — yes, unusually for this category: the source is published under GPLv2, and your engineers can read the very driver they are approving, a point genuinely in com0com&#8217;s favour that proprietary alternatives cannot match. <strong>&#8220;What is our exit?&#8221;</strong> — pairs are recreated in a replacement tool in minutes; applications address ports by COM name and never knew which driver manufactured them, so migration risk is low and reversible. Teams that walk in with those four answers prepared tend to walk out with an approval scoped to lab and development machines — which is, not coincidentally, the correct scope.</p>
<p>One more line belongs in the ticket even though nobody asks for it: the <em>workaround half-life</em>. Approving com0com &#8220;with Test Mode where needed&#8221; approves a permanent weakening of specific machines, and that exception will be rediscovered, out of context, at every future audit. Approving it &#8220;only where the signed package loads&#8221; is a self-limiting policy that ages well. The difference between those two sentences is the difference between a tool decision and a future finding.</p>
<h2>Contractors, customer sites and other people&#8217;s machines</h2>
<p>One scenario deserves its own paragraph: your software, or your engineers, working on machines you do not own — a customer&#8217;s plant, a partner&#8217;s lab. There, even a legally impeccable GPL tool meets a harder room: their signing policy, their audit, their change freeze. The professional pattern is to arrive with the commercial option already evaluated — a signed driver you can name, price and procure (<a href="/com0com-alternatives/">the alternatives survey</a>) — and let the customer choose which column of their risk register the installation lands in. Offering only the free tool reads as unprepared; offering both reads as engineering.</p>
<h2>The one-paragraph answer, for your IT ticket</h2>
<p>com0com is GPLv2 open source; internal commercial use is permitted by the license and costs nothing; the project itself makes no support or Windows 11 compatibility commitments and has been unmaintained since 2012; deployment is bounded by driver-signing policy, not law. Approve it for lab and development machines where the signed package loads, and budget a commercial signed driver or a device server anywhere policy, Secure Boot, or a support requirement says no. That paragraph has closed this question in more organisations than any feature matrix ever will.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/com0com-commercial-use/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>USB to Serial Adapter Buying Guide: FTDI, Prolific, CH340 and the Clone Trap</title>
		<link>https://com0com.com/usb-to-serial-adapter-guide/</link>
					<comments>https://com0com.com/usb-to-serial-adapter-guide/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 07:00:00 +0000</pubDate>
				<category><![CDATA[Comparisons & Buying]]></category>
		<guid isPermaLink="false">https://com0com.com/usb-to-serial-adapter-guide/</guid>

					<description><![CDATA[Every USB-to-serial adapter looks identical in the product photo: a USB plug, a DB9, a translucent blue shell. The difference between the one that works for a decade and the one that generates a weekend of Device Manager archaeology is a chip you cannot see and a driver story nobody prints on the box. This...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Every USB-to-serial adapter looks identical in the product photo: a USB plug, a DB9, a translucent blue shell. The difference between the one that works for a decade and the one that generates a weekend of Device Manager archaeology is a chip you cannot see and a driver story nobody prints on the box. This guide is the chipset truth, the cable questions that actually matter, and a checklist for the hardest case — keeping legacy industrial equipment alive. It assumes you already know you need hardware; if both ends of your conversation live on one PC, you want <a href="/virtual-serial-port/">virtual ports</a> instead, and they&#8217;re free.</p>
<h2>The chipset landscape, honestly</h2>
<p><strong>FTDI</strong> is the safe answer. Genuine FTDI chips (the FT232 family is the household name) have the most painless driver story in the business: drivers are mature, come through official channels including Windows Update, and the chips behave identically decade after decade — which is why instrument makers build them in. You pay a premium over no-name adapters, and it is the premium this whole guide exists to justify. One caution travels with the brand: FTDI&#8217;s popularity made it a counterfeiting target, so buy through reputable sellers rather than the absolute cheapest listing.</p>
<p><strong>Prolific</strong> is where the famous pain lives, and precision matters here. Prolific&#8217;s own current chips are fine. The disaster is the flood of cloned PL2303 chips in bargain adapters: Prolific&#8217;s official drivers detect non-genuine silicon and refuse it, which is why the internet is full of &#8220;Prolific adapter stopped working after an update&#8221; stories. The rule that falls out of this: <strong>cheap no-name adapters with cloned chips are the number one cause of driver pain in this entire category</strong> — not Windows, not your software. A genuine-Prolific adapter from a named vendor is a legitimate mid-priced choice; a bargain-bin mystery cable is a lottery ticket.</p>
<p><strong>CH340</strong> (from WCH) is the honest budget chip. It is the silicon inside countless Arduino-compatible boards and low-cost adapters; official drivers exist from WCH, Windows installs are uneventful, and for ordinary data rates and tolerant software it simply works. What you give up versus FTDI is the deep track record with fussy legacy software and exotic baud rates. Silicon Labs&#8217; CP210x family sits in the same respectable tier — common inside equipment, properly supported, rarely the villain of anyone&#8217;s story.</p>
<h2>Null-modem vs straight-through: the cable is part of the adapter decision</h2>
<p>A USB-to-serial adapter presents itself as a DTE — a computer personality. Two DTEs cannot talk over a straight cable: both transmit on the same pin. So if your target is another computer or a device wired as DTE, you need the transmit/receive crossover somewhere: a null-modem cable or adapter in series with your USB adapter (the full explanation and the two-minute link test are in <a href="/virtual-null-modem-cable/">null-modem cable vs virtual null modem</a>). If your target is a modem-style device (DCE) — most instruments, scales, and industrial gear — straight-through is correct and a null-modem cable will produce eerie silence. Check the device manual for the word &#8220;null modem&#8221;; when the manual is lost, the two-minute terminal test settles it empirically.</p>
<h2>RS-232 vs RS-485: different electricity, not different plugs</h2>
<p>Buyers regularly purchase one expecting the other. RS-232 is single-ended, one device per port, short-haul — the PC classic. RS-485 is differential, multi-drop, long-distance, and the fieldbus of the industrial world (Modbus RTU runs on it; our <a href="/modbus-rtu-simulation/">Modbus simulation guide</a> covers the protocol side). A USB-to-RS-485 converter is a different product from a USB-to-RS-232 adapter with the same-shaped shell, and no driver on earth converts one into the other. For 485 work, prefer converters with proper termination/biasing options and galvanic isolation if the two ends live on different power domains — factory floors punish optimism here.</p>
<h2>Before you buy for legacy industrial gear</h2>
<ul>
<li><strong>True RS-232 levels vs TTL.</strong> Some &#8220;serial&#8221; devices speak TTL-level UART (0–3.3/5 V), not RS-232&#8217;s bipolar signalling. A standard adapter will not hurt them, but it will never talk to them either; those need a TTL adapter, often a bare board. Check the manual for &#8220;TTL&#8221; or voltage levels before anything else.</li>
<li><strong>Handshake lines.</strong> Old equipment frequently refuses to communicate until it sees DTR/DSR or RTS/CTS behave. Confirm your adapter breaks out and correctly drives the full line set — most decent ones do; converter dongles that carry only TX/RX/GND are for consoles, not for picky machinery.</li>
<li><strong>Connector reality.</strong> DB9 on the adapter is standard; the machine may be DB25, RJ45, or a terminal block. Adapters and gender changers are cheap; discovering the mismatch on a ladder is not.</li>
<li><strong>Baud and timing oddities.</strong> Legacy gear with unusual baud rates or strict timing is where genuine-chipset adapters earn their price and where virtual-pair baud emulation (com0com&#8217;s EmuBR) helps on the software side.</li>
<li><strong>Driver support for your Windows.</strong> The whole chipset section above, compressed: if the vendor cannot point you to a current, signed, official driver, the adapter is e-waste with good packaging.</li>
</ul>
<p>Two boring specifications deserve their thirty seconds. <strong>Activity LEDs</strong> — a TX/RX blink pair on the adapter body — sound like decoration and are in fact the cheapest serial debugger ever sold: half of all &#8220;my device won&#8217;t talk&#8221; cases resolve into &#8220;nothing is transmitting&#8221; versus &#8220;it transmits and nothing answers&#8221;, and the LEDs tell you which before any software is opened. <strong>Cable length and retention</strong> matter at the margins: USB&#8217;s practical limits mean the adapter generally lives near the PC with the serial run doing the travelling (RS-232 is rated for modest distances and often works well beyond them at low baud), and on anything that moves or vibrates, a latching or screwed connection outperforms good intentions.</p>
<h2>Reading a listing like an engineer</h2>
<p>Product pages for adapters are a genre of fiction, but a decipherable one. The details that predict your experience, in the order to look for them: <strong>the chipset, named explicitly</strong> — &#8220;FT232&#8221; or &#8220;CH340&#8221; in the specifications, not &#8220;high-speed chip&#8221; in the headline; a listing that hides the silicon is telling you it is cloned. <strong>The full pin set</strong> — TX, RX, ground and the handshake lines broken out, which picky legacy devices will demand. <strong>Isolation and surge protection</strong>, offered on industrial-grade models and worth real money between buildings or power domains. <strong>Cable retention and strain relief</strong>, because the most common field failure is mechanical, and a screw-locked DB9 beats a friction fit on anything that vibrates. <strong>A driver link on the vendor&#8217;s own site</strong>, current and signed — check it before the package arrives, not after. Listings that score well on those five lines are boring in exactly the way infrastructure should be.</p>
<h2>Where the adapter meets the virtual world</h2>
<p>The most useful setups in this whole field are hybrids. A real device arrives on a USB adapter as, say, COM5; two programs need it; so hub4com fans COM5 out into com0com pairs, and both programs are satisfied — the pattern behind our <a href="/share-gps-multiple-apps/">GPS sharing recipe</a> and the <a href="/split-serial-port/">port splitting guide</a>. The buying consequence is easy to miss: in a hybrid setup, the adapter is the single physical point of failure for every program downstream, which argues for buying the adapter one tier better than the application seems to need. A small saving on the adapter is expensive on the day it takes three programs down with it.</p>
<p>One more population deserves a sentence: console ports. The USB-to-serial adapter&#8217;s other day job is talking to network switches, routers and headless machines whose console is a serial port — often with vendor-specific pinouts hiding behind an RJ45 jack. The chipset rules are identical, the cable question belongs to the console cable, and a known-good adapter in the laptop bag is the difference between a configuration session and a very quiet afternoon in a cold aisle.</p>
<h2>The shortlist</h2>
<p>We link searches rather than specific listings, because adapter stock and branding churn constantly while the chipset advice does not: <a href="/go/amazon-usb-serial" rel="sponsored nofollow">USB-to-serial adapters on Amazon</a>, <a href="/go/amazon-null-modem" rel="sponsored nofollow">null-modem cables and adapters on Amazon</a>, and <a href="/go/amazon-rs485" rel="sponsored nofollow">USB-to-RS-485 converters on Amazon</a> (all sponsored). Filter by the chipset first — FTDI for the gear you cannot afford to fight, CH340 or genuine Prolific for the bench — and treat any listing that refuses to name its chip as having named it.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/usb-to-serial-adapter-guide/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Null-Modem Cable vs Virtual Null Modem: When You Need the Real Cable</title>
		<link>https://com0com.com/virtual-null-modem-cable/</link>
					<comments>https://com0com.com/virtual-null-modem-cable/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 06:00:00 +0000</pubDate>
				<category><![CDATA[Comparisons & Buying]]></category>
		<guid isPermaLink="false">https://com0com.com/virtual-null-modem-cable/</guid>

					<description><![CDATA[Somewhere in every serial-port project comes the question: do I need an actual null-modem cable, or the software that imitates one? They share a name because they do the same job — but in different places, and picking wrong wastes either a purchase or an afternoon. Here is the distinction, drawn sharply: a null-modem cable...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Somewhere in every serial-port project comes the question: do I need an actual null-modem cable, or the software that imitates one? They share a name because they do the same job — but in different places, and picking wrong wastes either a purchase or an afternoon. Here is the distinction, drawn sharply: <strong>a null-modem cable connects two physical machines (or a machine and a device); a virtual null modem connects two programs inside one machine. Software can never join two separate computers.</strong> Everything else is detail.</p>
<h2>What a null-modem cable actually is</h2>
<p>Serial ports come in two personalities: DTE (the computer) and DCE (the modem, historically). A normal &#8220;straight-through&#8221; cable assumes one of each: pin 2 transmits here and arrives at pin 3 there because the modem&#8217;s pins are mirrored. Connect two computers straight-through and both shout into pin 2 while listening on pin 3 — silence. A null-modem cable removes the imaginary modem: inside the cable, transmit crosses to receive (2↔3), and the handshake lines are crossed or looped back in matching pairs, so each computer believes it is talking to a modem that is always ready. That is the whole invention — a cable that lies, electrically, in a useful way.</p>
<table>
<thead><tr><th>DB9 pin</th><th>Signal</th><th>Null-modem treatment</th></tr></thead>
<tbody>
<tr><td>3</td><td>TX — transmit</td><td>Crosses to pin 2 of the other end</td></tr>
<tr><td>2</td><td>RX — receive</td><td>Crosses to pin 3 of the other end</td></tr>
<tr><td>5</td><td>Ground</td><td>Straight through</td></tr>
<tr><td>7 / 8</td><td>RTS / CTS</td><td>Crossed in full-handshake cables</td></tr>
<tr><td>4</td><td>DTR</td><td>Crossed to the other end&#8217;s DSR (pin 6, often with DCD, pin 1)</td></tr>
</tbody>
</table>
<p>In practice you will meet two grades of the lie. A simple three-wire cable crosses TX/RX and carries ground; fine for software that ignores handshaking. A full-handshake cable (or adapter) also crosses or loops RTS/CTS and DTR/DSR/DCD, which older industrial and instrument software often insists on seeing before it will say a word. If a cable &#8220;should work&#8221; but a program never starts talking, handshaking is the usual suspect.</p>
<h2>When you need the physical cable</h2>
<ul>
<li><strong>Two separate PCs must exchange serial data</strong> — a modern machine talking to a vintage one, a laptop interrogating an embedded board&#8217;s console, two test rigs. Two machines means electricity must cross the gap; that is a cable&#8217;s (or a network&#8217;s) job, never a driver on one side.</li>
<li><strong>A PC must talk to a real serial device</strong> whose other &#8220;end&#8221; is firmware — a scale, a CNC controller, a data logger, a radio. If the device expects a DTE partner wired as its modem, you need the crossed wiring, in an adapter or a cable.</li>
<li><strong>The other end has no software you can install</strong> — sealed instruments, legacy PLCs, anything you may not modify. Physical problems get physical solutions.</li>
</ul>
<h2>When software is the answer</h2>
<p>If both ends of the conversation are programs on the <em>same</em> PC — your application and its simulator, two test tools, a logger tapping a data stream through a pair — a cable is absurd and a virtual null-modem pair is the tool: two COM ports wired back-to-back in the kernel. That is what com0com creates, free; the walkthrough is <a href="/create-virtual-com-port-pair/">creating your first pair</a>, and the wider landscape from free to signed is covered in <a href="/com0com-alternatives/">com0com alternatives</a>. Modern PCs also have no serial port at all, which settles many arguments by itself: there is nowhere to plug the cable into, while the virtual pair needs nothing physical.</p>
<h2>Cables, adapters and gender changers: the physical forms</h2>
<p>The null-modem function comes in three physical packages, and the choice is about tidiness, not behaviour. A <strong>null-modem cable</strong> has the crossover wired along its length — one less joint to fail, and the right answer for a permanent run between two machines. A <strong>null-modem adapter</strong> is the crossover in a stubby DB9 body that converts any straight cable; it is the diagnostician&#8217;s friend, because it can be inserted or removed in seconds when you are not sure which wiring a device expects. <strong>Gender changers</strong> do no crossing at all — they exist because both your cable and your device presented the same connector sex, and they are bought in pairs and with regret. When in doubt, the adapter wins: the two-minute test below turns &#8220;is it the wiring?&#8221; from a purchase into a thirty-second experiment.</p>
<p>One modern wrinkle: the &#8220;two PCs&#8221; are often two laptops with no serial ports at all, so the full physical chain becomes USB adapter, null-modem cable, USB adapter. That chain works fine, and each adapter receives its own COM number on its own machine — but it is also the moment to price the network option at the end of this page, because two adapters and a cable buy a great deal of Ethernet.</p>
<h2>DB9, DB25 and the connector zoo</h2>
<p>One more physical reality before you order: &#8220;serial port&#8221; is a function, not a shape. The original RS-232 connector was the 25-pin DB25; the PC world shrank it to the 9-pin DB9 (strictly, DE9) that adapters wear today; network equipment hides the same signals in RJ45 console ports with vendor-specific pinouts; and industrial gear may present bare screw terminals. None of these change the electrical conversation — a passive adapter between DB9 and DB25 is just wires landing on the right pins — but each end of your run must be inventoried before you buy, because the correct order is &#8220;a null-modem cable in the connectors both ends actually have&#8221;, and the incorrect order is the one that arrives. When the far end is a console port on network equipment, its own console cable is part of the run, and the null-modem question is answered by that cable&#8217;s design rather than yours.</p>
<h2>Buying the cable (and the port to plug it into)</h2>
<p>If your setup is in the physical camp, the shopping list is short and cheap. You need a null-modem cable or adapter with the right connectors for both ends (DB9 female-to-female is the classic; check your device, DB25 still roams the industrial wild), wired for full handshaking if your software is old or unknown. And if the PC end is any machine built in the last decade, it has no serial port, so you also need a USB-to-serial adapter — at which point the chipset advice in the <a href="/usb-to-serial-adapter-guide/">adapter buying guide</a> applies: the cable can be perfect and the adapter can still ruin your week. Current options, both sponsored: <a href="/go/amazon-null-modem" rel="sponsored nofollow">null-modem cables on Amazon</a> and <a href="/go/amazon-usb-serial" rel="sponsored nofollow">USB-to-serial adapters on Amazon</a>.</p>
<h2>Wiring two real PCs: the two-minute test</h2>
<p>Once the cable (and adapters, if any) are in place, prove the link before involving your real software:</p>
<ul>
<li>On each PC, note which COM port the cable arrived as (Device Manager → Ports). If one side is a USB adapter, this is where you learn its assigned number.</li>
<li>Open a terminal on both ends — the settings ritual is in the <a href="/putty-loopback-test/">PuTTY loopback test</a> guide: same speed on both sides (start at 9600), 8 data bits, no parity, 1 stop bit, and flow control set to <strong>None</strong> for a first test.</li>
<li>Type in one terminal. The characters should appear in the other. Type back. Two-way text means wiring, ports and settings are all correct, and any remaining problem belongs to your application, not the link.</li>
<li>Nothing arriving? Swap your suspicion in order: flow control still on, mismatched speeds, a straight-through cable sold as null-modem (more common than anyone admits), then the handshake-hungry program problem described above.</li>
</ul>
<h2>The third option nobody mentions: the network</h2>
<p>Two machines that both have Ethernet often do not need a serial cable at all — one machine can expose its serial port over TCP and the other can connect a virtual port to it, which is the entire subject of our <a href="/rfc2217-server-client/">RFC 2217 recipes</a> and the <a href="/com2tcp-guide/">com2tcp guide</a>. The cable is local, simple and electrons-honest; the network is flexible. Know which problem you have, buy (or download) exactly that, and may your TX always find an RX.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/virtual-null-modem-cable/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Free Virtual Serial Port Software: What &#8216;Free&#8217; Really Costs</title>
		<link>https://com0com.com/free-virtual-serial-port-software/</link>
					<comments>https://com0com.com/free-virtual-serial-port-software/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 05:00:00 +0000</pubDate>
				<category><![CDATA[Comparisons & Buying]]></category>
		<guid isPermaLink="false">https://com0com.com/free-virtual-serial-port-software/</guid>

					<description><![CDATA[Free virtual serial port software absolutely exists, and the best of it is excellent — the tool this whole site is about has been free since 2005. But &#8220;free&#8221; in this category comes with one specific, predictable friction that listicles never mention, and it is better to meet it here than in Device Manager. This...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Free virtual serial port software absolutely exists, and the best of it is excellent — the tool this whole site is about has been free since 2005. But &#8220;free&#8221; in this category comes with one specific, predictable friction that listicles never mention, and it is better to meet it here than in Device Manager. This page lists the genuinely free options by the job they do, then explains the catch and the exact free path through it.</p>
<h2>The free tools, by job</h2>
<h2>com0com — free pairs, the full toolkit</h2>
<p>com0com (with its companion hub4com) is the most capable free offering in this category, full stop. It creates virtual null-modem pairs at kernel level — as many as you need; the project&#8217;s own FAQ puts the internal limit at 1,000,000 pairs — renames them to real COM names your programs can see, emulates baud-rate pacing and receive overruns for testing, and is scriptable end-to-end through the setupc command line. hub4com adds the sharing and networking half: splitting a physical port across several programs, bridging ports to TCP, and RFC 2217 client/server work. All of it is GPLv2 open source, free for any use including at work (the <a href="/com0com-commercial-use/">commercial use question</a> is about policy, not price). Get it from the <a href="/download/">download page</a>, where both the signed and unsigned SourceForge packages carry published SHA-256 checksums.</p>
<h2>HHD Free Virtual Serial Port — the commercial shop&#8217;s free tier</h2>
<p>HHD Software&#8217;s free edition creates a virtual pair aimed at serial-application testing, and costs $0; the paid edition is $89.99. Treat it the way you would any free tier of a commercial product: a real tool with a sales funnel attached. It is a legitimate second option if you want to compare pair behaviour between two drivers, or if its interface happens to suit you better. Just apply the same question to it as to everything on this page: whose signature does the driver carry, and will your machine load it?</p>
<h2>HW VSP3 — free, but a different animal</h2>
<p>HW VSP3 costs nothing and creates a virtual COM port — that talks to a device over your network via TCP. It is a redirector, not a pair emulator: there is no second port inside your PC for another program to hold the other end of. For reaching a networked serial device from software that insists on a COM port, it is a neat free solution for a single port. Note the product is in run-out; it is a finished utility, not a living platform.</p>
<h2>VSP Manager — free if you hold an amateur licence</h2>
<p>In the ham radio niche, VSP Manager is free for licensed amateur radio operators and built for the classic one-rig-port-many-programs tangle. If that is you, it belongs at the top of your list alongside the pair-plus-split patterns in our <a href="/ham-radio-virtual-com-ports/">ham radio guide</a>. If that is not you, it is not your free option — licensure is the price.</p>
<h2>And on Linux: socat</h2>
<p>One line, for completeness: Linux users get linked pseudo-terminal pairs from socat, free, built-in philosophy, no signing saga at all.</p>
<h2>So what does &#8220;free&#8221; actually cost?</h2>
<p>Here is the part the listicles skip. Since 64-bit Windows became the norm, loading a kernel driver requires a signature Microsoft accepts. Obtaining and maintaining that signature is a recurring commercial expense — which is precisely why so many tools in this category are paid, and why VSPE, for instance, gives its 32-bit build away and charges for the 64-bit one. com0com never paid: the driver is test-signed, and the &#8220;signed&#8221; SourceForge package leans on a legacy CyberCircuits cross-signature that modern Windows honours only in narrowing exceptions. The practical consequence sorts free-tool users into three groups:</p>
<ul>
<li><strong>The signed package just installs.</strong> True for a large share of Windows 10/11 machines. Your total cost was a download. You are done; ignore everything below.</li>
<li><strong>Code 52.</strong> The driver refuses to load. You still have a free path — Test Mode, <code>bcdedit -set TESTSIGNING ON</code>, which tells Windows to accept test-signed drivers. It works, it is officially documented by the project, and it is a real security trade-off: you are lowering the barrier for <em>any</em> test-signed driver, and the desktop watermark will remind you. The full, careful walk-through is the <a href="/com0com-test-mode/">Test Mode guide</a>, and the diagnosis lives in <a href="/fix-com0com-code-52/">fix Code 52</a>.</li>
<li><strong>Test Mode is not available.</strong> Secure Boot policy blocks test signing on some machines, and employers block it on the rest (<a href="/com0com-secure-boot/">Secure Boot explained</a>). On those machines the free path genuinely ends — not because the software costs money, but because the machine&#8217;s owner (you, or your IT department) has decided unsigned kernel code does not run there.</li>
</ul>
<p>Add the second, quieter cost: maintenance. The flagship free tool has been dormant since 2012. It still works — Windows&#8217; driver model has been kind to it — but nobody is on call when a future Windows release changes the rules. For a home lab that is a shrug; for a production line it is a line item, and it is the respectable reason some people pay.</p>
<h2>A note on sources, before the cost section</h2>
<p>Free drivers attract repackagers the way free anything does: the same tools listed above circulate on download portals wrapped in installers nobody asked for. The rule costs nothing and prevents the worst outcome in this entire category: take com0com only from its SourceForge project (the <a href="/download/">download page</a> here links the packages with their published SHA-256 checksums, so you can verify the file byte-for-byte), HHD&#8217;s tool only from HHD, HW VSP3 only from HW group. A kernel driver is the most privileged code you will install this year; its provenance deserves the same care as its price tag.</p>
<h2>Free as in beer, free as in freedom</h2>
<p>The free tools split into two species worth distinguishing. com0com is open source: GPLv2, source published, forkable, auditable, and legally usable in any environment including commercial ones (the <a href="/com0com-commercial-use/">commercial-use analysis</a> works through what that means inside a company). Its freedom is the structural kind — no vendor can discontinue it, raise its price, or move your favourite feature behind a tier. HHD&#8217;s free edition is freeware: a proprietary product whose zero-price tier is part of a commercial catalogue. That is not a criticism — it may suit you perfectly — but the zero is a pricing decision, revocable at the vendor&#8217;s convenience, and the tool&#8217;s future is a line in someone else&#8217;s roadmap. HW VSP3 sits in a third state: free, finished, in run-out — no roadmap at all, which is its own kind of stability.</p>
<h2>Keeping a free setup alive</h2>
<p>Because free tools come without a support desk, the support system is a folder of your own notes. Three habits keep a com0com installation boring for years. <strong>Record your configuration:</strong> <code>setupc list</code> prints your pairs and their settings; save that output with your project files, and recreating a setup on a new machine becomes transcription instead of archaeology. <strong>Change one variable at a time:</strong> most &#8220;com0com broke&#8221; stories are Windows updates, new security software, or a port renamed by something else — the <a href="/com0com-not-working-after-windows-update/">after-an-update guide</a> exists because the driver almost never breaks alone. <strong>Pin your expectations:</strong> the tool will not gain features; what it does today — pairs, renaming, baud and overrun emulation, hub4com routing — is the complete and final feature set, and planning around that fact is what makes free sustainable instead of fragile.</p>
<p>It is also worth pricing your own time once, honestly. If the signed package installs, free costs you fifteen minutes. If you spend two evenings negotiating with Code 52 on a machine you depend on, free has quietly cost more in attention than the mid-tier commercial licence would have cost in money — which is not an argument to pay, but a reminder that &#8220;free&#8221; is a price in a currency of attention, and some weeks you are rich in it and some weeks you are not.</p>
<h2>The free decision path, in order</h2>
<p>One: install the signed package and check Device Manager. Two: if Code 52 appears and the machine is yours, weigh Test Mode honestly — fine for a bench PC, questionable for your daily driver. Three: if neither works, your problem is no longer &#8220;find free software&#8221;; it is &#8220;this machine requires a properly signed driver&#8221;, and the paid comparison, with the same honesty about what the money buys, is <a href="/com0com-alternatives/">com0com alternatives</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/free-virtual-serial-port-software/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Best Virtual Serial Port Software for Windows</title>
		<link>https://com0com.com/best-virtual-serial-port-software/</link>
					<comments>https://com0com.com/best-virtual-serial-port-software/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 04:00:00 +0000</pubDate>
				<category><![CDATA[Comparisons & Buying]]></category>
		<guid isPermaLink="false">https://com0com.com/best-virtual-serial-port-software/</guid>

					<description><![CDATA[&#8220;Best virtual serial port software&#8221; is a broken question until you add &#8220;for what&#8221;. The tools in this category do three different jobs — creating pairs of virtual ports inside one PC, splitting a real port between programs, and putting a serial port on the network — and the best tool for each job is...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">&#8220;Best virtual serial port software&#8221; is a broken question until you add &#8220;for what&#8221;. The tools in this category do three different jobs — creating pairs of virtual ports inside one PC, splitting a real port between programs, and putting a serial port on the network — and the best tool for each job is a different program. So instead of a fake overall winner, here are the picks by job, with prices, and with the one factor that actually separates them in 2026: <strong>whether their Windows driver signature survives a modern, Secure Boot machine</strong>. If you want the concepts explained first, the <a href="/virtual-serial-port/">virtual serial port guide</a> is the explainer; this page is the verdicts.</p>
<table>
<thead><tr><th>Pick</th><th>Tool</th><th>Price</th></tr></thead>
<tbody>
<tr><td>Best free pair driver</td><td>com0com</td><td>Free (GPLv2)</td></tr>
<tr><td>Best properly signed</td><td>Eltima Virtual Serial Port Driver</td><td>$89.95 / $199.95</td></tr>
<tr><td>Best splitter</td><td>VSPE</td><td>$49.95 (32-bit free)</td></tr>
<tr><td>Best budget pair driver</td><td>AGG Virtual Null Modem</td><td>$35</td></tr>
<tr><td>Best for one port on the network</td><td>HW VSP3</td><td>Free</td></tr>
</tbody>
</table>
<p>All prices as of October 2026 — confirm on the vendor&#8217;s site, prices in this niche do move.</p>
<h2>Best free: com0com</h2>
<p>For creating virtual COM port pairs — two ports cabled together in software so two programs can talk — com0com remains the reference tool a generation of developers, testers and radio amateurs built their setups on. It is kernel-level, scriptable through setupc, can emulate baud-rate pacing and receive overruns for testing cantankerous software, and extends with hub4com into sharing and network bridging. It is also free and open source (GPLv2), rated 4.4/5 across 64 SourceForge reviews. The catch is singular and famous: its driver is test-signed, the SourceForge signed package relies on a legacy cross-signed certificate, and so on some Windows 11 machines it installs in minutes and on others it is a <a href="/fix-com0com-code-52/">Code 52</a>. Try it first — <a href="/download/">download page</a> — because if your machine accepts it, every other pick on this page is money for nothing. If your budget is strictly zero and you want every free option compared on its own terms, see our <a href="/free-virtual-serial-port-software/">free virtual serial port software</a> survey.</p>
<h2>Best properly signed: Eltima Virtual Serial Port Driver</h2>
<p>The pick for when com0com&#8217;s signing is the problem: a work laptop you do not control, Secure Boot and memory integrity enforced, a policy that laughs at Test Mode. Eltima&#8217;s driver carries a proper Microsoft signature, so it installs like ordinary commercial software, and it comes with a full settings GUI and a vendor to email. Standard is $89.95, Pro $199.95, with a 14-day trial — take the trial and confirm the install on your actual machine before paying, since the install is the entire point. Vendor page: <a href="/go/eltima-vspd" rel="sponsored nofollow">Eltima Virtual Serial Port Driver</a> (sponsored). The full reasoning is in <a href="/com0com-vs-eltima-vspd/">com0com vs Eltima VSPD</a>.</p>
<h2>Best splitter: VSPE</h2>
<p>When the problem is one physical port and several hungry programs — a GPS, a radio, an instrument — creating pairs is only half the answer; something must fan the real port out. VSPE ($49.95; 32-bit build free) does splitting, joining and pair creation in one tool, which is why it owns this pick. The free route to the same end state is com0com plus hub4com (<a href="/split-serial-port/">splitting walkthrough</a>), and licensed hams should also know VSP Manager, free to them. But as a single-purpose answer to &#8220;share this port&#8221;, VSPE is the pick.</p>
<h2>Best budget pair driver: AGG Virtual Null Modem</h2>
<p>Sometimes the analysis is: com0com will not load, Test Mode is banned, and Eltima&#8217;s $89.95 feels steep for a utility. AGG&#8217;s Virtual Null Modem, at $35, is the cheapest commercial pair driver with a legitimate licence — a narrower tool from a smaller vendor, priced accordingly. FabulaTech&#8217;s Virtual Serial Port Kit ($129.95) is the other commercial pair driver worth knowing; it is a perfectly real product that simply lands in an awkward middle for most buyers — more than AGG, overlapping Eltima&#8217;s territory.</p>
<h2>Best for the network: HW VSP3, then hardware</h2>
<p>If &#8220;virtual serial port&#8221; to you means &#8220;a COM port whose device is down the hall or across the site&#8221;, pair drivers are the wrong shelf. HW VSP3 is a free redirector that points a virtual COM port at a device on the network over TCP — one port, no pair emulation, and the product is in run-out, so enjoy it as a free legacy utility. Beyond one port, the category answer stops being software: a serial device server puts real serial hardware on the network permanently, which is what industrial sites actually deploy. Our <a href="/rfc2217-server-client/">RFC 2217 recipes</a> show the protocol these setups speak.</p>
<h2>What to avoid</h2>
<p>Three traps recur in this niche. First, &#8220;driver updater&#8221; bundles that offer to fix virtual COM problems for a subscription — they are not serial tools, they are adware with a settings page, and no pick above needs them. Second, patched or &#8220;cracked&#8221; driver downloads, especially repackaged com0com builds: a kernel driver from an unverifiable source is the single worst thing you can install on a Windows machine, and the legitimate packages are free from SourceForge with published checksums. Third, paying for pair software before discovering whether your actual problem was splitting or networking — the two most common reasons people buy the wrong tool on this page.</p>
<h2>How these picks were made</h2>
<p>Three tests, applied in order. <strong>First, the signature test:</strong> does the driver install on a current Windows 11 machine with Secure Boot and memory integrity on, without weakening the machine? This is a pass/fail gate that eliminates more products than any feature comparison — it is why the signed pick exists as a category at all. <strong>Second, the job test:</strong> does the tool actually do the job in its pick — pairs, splitting, or network — as a first-class function rather than a side effect? HW VSP3 fails pairs and passes network; VSPE passes splitting outright; com0com passes pairs at kernel level. <strong>Third, the honesty test:</strong> is the price printed on the vendor&#8217;s own site, the licence real, and the download the vendor&#8217;s own? Tools that arrive via &#8220;driver updater&#8221; bundles or repackaged downloads fail this test regardless of merit, which is why none appear above.</p>
<p>Notice what is not a test: raw throughput. Every serious tool here moves serial data inside the kernel or over a local network at rates bounded by the applications at the ends — a terminal, a logger, a PLC poll cycle. Nobody&#8217;s virtual port is the bottleneck in a 9600-baud world, or even a 921600-baud one, and any product page implying otherwise is telling you about its marketing department. A fourth consideration runs underneath all three: whether anyone still maintains the tool. com0com has been dormant since 2012 and passes on merit anyway — but a buyer should know that this is the bet being made.</p>
<p>One more pick-shaped note, on the network row: HW VSP3 wins its line because it is free and does one network port well, but the moment the requirement reads &#8220;several ports, several buildings, someone on call&#8221;, the correct purchase is a serial device server — hardware from the industrial networking world, with a vendor redirector for the PC side. Software picks have a ceiling, and operations teams hit it quickly; plan the jump rather than discovering it during an outage.</p>
<h2>How the picks connect</h2>
<p>This page is the category verdict; <a href="/com0com-alternatives/">com0com alternatives</a> is the same field viewed from a com0com user&#8217;s chair — start there if you are migrating away from com0com specifically, start here if you are choosing cold. Either way, the order of operations is the same: define the job (pairs, split, or network), test the free tool for that job, and spend money only on the specific property the free tool lacks — a signature, an interface, or a support contract.</p>
<p>And if the free tool fails the signature test on a machine you own and control, do not skip the one remaining free move before reaching for a card: Test Mode exists, is documented, and on a bench or development machine is a legitimate choice made with open eyes — the <a href="/com0com-test-mode/">Test Mode guide</a> covers exactly what you are accepting and how to reverse it. Paid software should be bought for what it is, a signature and a vendor, not purchased in a panic at the first yellow exclamation mark in Device Manager.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/best-virtual-serial-port-software/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>com0com vs VSPE: Pairs, Splitting and the 64-Bit Question</title>
		<link>https://com0com.com/com0com-vs-vspe/</link>
					<comments>https://com0com.com/com0com-vs-vspe/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 03:00:00 +0000</pubDate>
				<category><![CDATA[Comparisons & Buying]]></category>
		<guid isPermaLink="false">https://com0com.com/com0com-vs-vspe/</guid>

					<description><![CDATA[com0com and VSPE get compared constantly, and the comparison starts from a misunderstanding: they are not quite the same kind of tool. com0com is a pair factory — it creates virtual null-modem pairs, two COM ports wired back-to-back inside your PC, and nothing else. VSPE (Virtual Serial Ports Emulator, by Eterlogic) is a serial workbench:...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">com0com and VSPE get compared constantly, and the comparison starts from a misunderstanding: they are not quite the same kind of tool. com0com is a pair factory — it creates virtual null-modem pairs, two COM ports wired back-to-back inside your PC, and nothing else. VSPE (Virtual Serial Ports Emulator, by Eterlogic) is a serial <em>workbench</em>: it creates pairs too, but its reason to exist is reshaping real ports — splitting one physical port so several programs can use it, joining ports together, and mapping ports onto TCP connections. Choosing between them starts with naming your actual problem.</p>
<h2>The splitter difference, in plain terms</h2>
<p>A Windows COM port is exclusive: the first program to open it owns it, and everyone else gets an error. So the moment your setup has <em>one physical device and three programs</em> — the classic case is a radio or a GPS feeding a logger, a map and a control app — a pair driver alone cannot help you. Something has to sit on the real port and fan the data out.</p>
<p>VSPE does that inside one program: create a &#8220;Splitter&#8221; device on the real port, and each program opens its own virtual port fed by the splitter. It is genuinely one download, one configuration screen, done. The com0com ecosystem does it in two pieces: com0com creates the pairs, and <a href="/hub4com-guide/">hub4com</a> — the companion tool from the same author — routes the physical port&#8217;s data into those pairs, so every program gets an end of its own. The recipe is written out in <a href="/split-serial-port/">splitting one serial port</a> and the <a href="/share-gps-multiple-apps/">GPS sharing guide</a>. It works, it is free, and it is visibly a two-tool, command-line-flavoured affair next to VSPE&#8217;s single window. That contrast — integrated versus assembled — is the honest core of this comparison.</p>
<h2>Pairs themselves</h2>
<p>For pure pairs, both are competent kernel-level tools, and com0com&#8217;s pairs carry some testing-oriented extras VSPE users sometimes go looking for: baud-rate emulation (EmuBR) for software that misbehaves at line speed, and receive-overrun emulation (EmuOverrun) to reproduce the fault where a slow reader misses characters. com0com pairs are also scriptable end-to-end through setupc, which suits automated test rigs. VSPE&#8217;s pair creation lives in its GUI and configuration files. Neither has a performance story worth paying for; the pipe is never the bottleneck.</p>
<h2>The 64-bit question, and what pricing tells you</h2>
<p>VSPE&#8217;s pricing is the most instructive number in this category: <strong>the 32-bit version is free; the 64-bit version costs $49.95</strong> (as of October 2026 — check the vendor site). Why would a vendor give away one build and charge for the other? Because 64-bit Windows demands properly signed kernel drivers, and getting a driver through Microsoft&#8217;s signing programme costs real money and ongoing compliance. The $49.95 is, in large part, the signing fee passed through to you. com0com never paid it — its driver is test-signed, its SourceForge signed package leans on a legacy cross-signed certificate, and so on 64-bit Windows 11 your choices are the certificate exception, <a href="/com0com-test-mode/">Test Mode</a>, or Code 52. VSPE&#8217;s price buys you out of that entire paragraph. Neither tool is &#8220;better&#8221; here; they made opposite decisions about who pays for trust — com0com&#8217;s users pay in friction, VSPE&#8217;s in cash.</p>
<h2>Verdicts by use case</h2>
<ul>
<li><strong>You only need pairs (development, testing, app-to-app links):</strong> com0com, free, and stop reading. If the signed package refuses your machine and Test Mode is not an option, VSPE&#8217;s $49.95 is the mid-price way out — or see the wider field in <a href="/com0com-alternatives/">com0com alternatives</a>.</li>
<li><strong>One physical port, several programs:</strong> VSPE if you value an afternoon; com0com + hub4com if you value $49.95. Both end states work; the hub4com route demands more of you.</li>
<li><strong>Ham radio:</strong> this is VSPE&#8217;s home crowd — rig control, logging and digital modes all hanging off one CAT port is the exact contention it was built for, and our <a href="/ham-radio-virtual-com-ports/">ham radio guide</a> covers the patterns (including VSP Manager, free for licensed hams, which belongs in the same conversation).</li>
<li><strong>Scripted lab and regression rigs:</strong> com0com + setupc. Creating, renaming and removing pairs from a batch file is the kind of thing GUI-first tools make awkward.</li>
<li><strong>Locked-down work machine:</strong> VSPE&#8217;s signed 64-bit build — or Eltima&#8217;s, if a bigger vendor matters to your procurement process. com0com&#8217;s signing story is the disqualifier here, not its engineering.</li>
</ul>
<h2>The network dimension</h2>
<p>Both ecosystems reach the network, by different routes. VSPE builds TCP mapping into the same program: a port can be exposed to, or fed from, a TCP connection without leaving the tool. The com0com side gets there via hub4com&#8217;s bundled com2tcp wrapper, which does the COM-to-TCP bridging as a separate, command-line step (recipes in the <a href="/com2tcp-guide/">com2tcp guide</a>). If your design is &#8220;serial here, Ethernet there, daily&#8221;, VSPE&#8217;s integration is kinder. If networking is an occasional stunt on top of a pair-based setup, the free route is perfectly serviceable, and you will find its pair half documented by a decade of public forum answers.</p>
<h2>A worked scenario: one GPS, three programs</h2>
<p>Make it concrete. A GPS receiver sits on COM1, physically. A chart plotter, a position logger and a time-sync utility all want its NMEA stream, and Windows will hand COM1 to exactly one of them. <strong>With VSPE:</strong> you open one program, define a splitter device that takes COM1 as its source and presents virtual ports, and point the three programs at those ports. One tool, one configuration, and the fan-out survives as a saved configuration you can reload at startup. <strong>With com0com + hub4com:</strong> you create two or three com0com pairs with setupc, then run hub4com to route COM1&#8217;s output into one end of each pair, and point each program at the other ends (<a href="/share-gps-multiple-apps/">the step-by-step GPS recipe</a>). The end state is functionally the same — every program receives the stream — reached with two tools and a command line instead of one window. Readers who live in terminals will call the second route &#8220;scriptable&#8221; and mean it as praise; readers equipping a boat or a club station will call the first route &#8220;finished&#8221; and mean the same.</p>
<p>One asymmetry hides inside the scenario: in the VSPE route, the tool that owns the physical port also owns the splitting policy in a single place; in the hub4com route, data flow and pair creation are separate concerns you can adjust independently — overkill for a GPS, genuinely useful when the routing gets complicated, with multiple sources, conditional forwarding or a logging tap watching the stream. Complexity is a cost until the day it is the feature.</p>
<h2>Documentation and the long tail of answers</h2>
<p>A quieter difference: com0com&#8217;s behaviours, error messages and setupc incantations have been documented by fourteen years of forum posts, simulator projects and ham-radio write-ups — whatever edge you hit, someone has hit it in public, including on this site. VSPE&#8217;s knowledge base is its vendor documentation plus its own user community: thinner in public, but there is an actual vendor to ask. Neither is a defect; they are the two standard shapes of tool knowledge, communal and commercial.</p>
<h2>Running both is allowed</h2>
<p>A final practical note: nothing forces a single winner on one machine. A common settled configuration keeps com0com for what it does best — scripted pairs for development and testing — and calls on VSPE only for the splitter jobs, where its integrated device earns the shelf space. The two drivers coexist without drama; the only discipline required is housekeeping, since a COM name can belong to exactly one port at a time. Keep a note of which tool owns which names (a saved <code>setupc list</code> output covers the com0com side), and the mixed setup stays boring for years — which, in serial communications, is the highest available praise.</p>
<h2>Bottom line</h2>
<p>Ask one question: <em>is a physical port involved, with more than one program wanting it?</em> If no, com0com is the free, proven answer and VSPE is a solution shopping for a problem. If yes, you are choosing between VSPE&#8217;s integrated splitter at $49.95 and the free two-tool route through hub4com — a fair fight between money and effort, where either choice is defensible. And whichever you pick, the pair-creation half of your setup is a solved problem: get com0com from the <a href="/download/">download page</a> and be running in minutes.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/com0com-vs-vspe/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>com0com vs Eltima Virtual Serial Port Driver</title>
		<link>https://com0com.com/com0com-vs-eltima-vspd/</link>
					<comments>https://com0com.com/com0com-vs-eltima-vspd/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 02:00:00 +0000</pubDate>
				<category><![CDATA[Comparisons & Buying]]></category>
		<guid isPermaLink="false">https://com0com.com/com0com-vs-eltima-vspd/</guid>

					<description><![CDATA[This is the most common either/or in virtual serial ports: com0com, free and open source since 2005, or Eltima&#8217;s Virtual Serial Port Driver, the commercial tool that costs $89.95 and up. The comparison is shorter than vendors on either side would like, because the two tools create equally good port pairs. They differ on exactly...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">This is the most common either/or in virtual serial ports: com0com, free and open source since 2005, or Eltima&#8217;s Virtual Serial Port Driver, the commercial tool that costs $89.95 and up. The comparison is shorter than vendors on either side would like, because the two tools create equally good port pairs. They differ on exactly one axis that matters — <strong>how Windows decides whether to trust the driver</strong> — plus the usual free-versus-commercial differences in polish and support. Everything below is organised around that reality.</p>
<table>
<thead><tr><th></th><th>com0com</th><th>Eltima VSPD</th></tr></thead>
<tbody>
<tr><td>Price</td><td>Free (GPLv2)</td><td>$89.95 Standard / $199.95 Pro, 14-day trial</td></tr>
<tr><td>Driver signing</td><td>Test-signed; SourceForge &#8220;signed&#8221; package uses a legacy CyberCircuits cross-signature</td><td>Proper Microsoft signature</td></tr>
<tr><td>Windows 11 install</td><td>Works on many machines; Code 52 on others; Test Mode as fallback</td><td>Installs normally, Secure Boot and memory integrity included</td></tr>
<tr><td>Interface</td><td>SetupG GUI + setupc command line</td><td>Full settings GUI</td></tr>
<tr><td>Support</td><td>None — project dormant since 2012</td><td>Vendor support</td></tr>
<tr><td>Source code</td><td>Available (GPLv2)</td><td>Proprietary</td></tr>
</tbody>
</table>
<p>Prices as of October 2026 — verify on the vendor&#8217;s site before purchasing.</p>
<h2>Signing: the whole ballgame</h2>
<p>com0com&#8217;s driver is test-signed. Out of the box, 64-bit Windows refuses to load test-signed kernel drivers, full stop. Two escape routes exist, and both have limits. The first is the community signed package distributed via the official SourceForge project: its installers are signed by CyberCircuits with a legacy cross-signed certificate — a scheme Microsoft retired years ago, which modern Windows still honours only in narrow exceptions (broadly, certificates issued before 29 July 2015 on machines that meet the conditions). Result: it installs cleanly on a large share of Windows 11 PCs and throws Code 52 on the rest, and nobody can tell you in advance which machine you have. The second route is Test Mode — <code>bcdedit -set TESTSIGNING ON</code> — which works, at the cost of deliberately lowering your machine&#8217;s driver-signing enforcement and wearing a desktop watermark as a reminder.</p>
<p>Eltima&#8217;s driver is signed through Microsoft&#8217;s current programme. It just installs: Secure Boot on, HVCI/memory integrity on, managed work laptop, no BIOS trips, no bcdedit, no watermark. When people call VSPD &#8220;the professional option&#8221;, this paragraph is the entire content of that claim. It is also a genuinely valuable property — on a locked-down machine it is the difference between a tool and a non-starter.</p>
<h2>Installing on Windows 11, side by side</h2>
<p>With com0com, the honest sequence is: try the signed package (five minutes); if Device Manager shows Code 52, decide whether Test Mode is acceptable on this machine; if it is not — and on work machines it almost never is — stop. Our <a href="/fix-com0com-code-52/">Code 52 guide</a> walks that decision tree in full. With Eltima, the sequence is: download, install, done — the same as any signed commercial driver. Neither experience reflects the quality of the pairs you get at the end; it is purely the toll each driver pays at the Windows gate.</p>
<h2>Interface and day-to-day use</h2>
<p>com0com gives you SetupG — a functional GUI that is, in the project&#8217;s own description, a wrapper around the setupc command-line tool — plus setupc itself for scripting: <code>setupc install - -</code> creates a pair, <code>setupc change CNCA0 PortName=COM8</code> renames one end. It is spartan, entirely sufficient, and scriptable in a way GUI tools often are not. Eltima gives you a modern settings window where pairs are created, named and adjusted without touching a console. If you create pairs once and forget them, this difference is worth nothing. If you reconfigure ports weekly, or you are equipping colleagues who will not read a command reference, it is worth real money.</p>
<h2>Feature parity, at the documented level</h2>
<p>Both tools create persistent virtual pairs that appear as standard COM ports; both let you give the ends real COM names instead of internal ones; both pass data between the ends inside the kernel. com0com additionally emulates baud-rate pacing (EmuBR) and receive overruns (EmuOverrun) for testing awkward legacy software, and its pairs can be shared and redirected further with hub4com. VSPD is a broader commercial product with the vendor&#8217;s own extra tooling and licence tiers. For the core job the category exists for — two programs talking through a virtual null-modem — neither tool&#8217;s users are missing anything the other has. Claims of dramatic speed differences between kernel pair drivers are marketing; both are bounded by the programs at the ends, not the pipe.</p>
<h2>Who should pay, and who should not</h2>
<p><strong>Pay for Eltima if:</strong> the machine is employer-managed or Secure Boot-locked and Test Mode is against policy; you are equipping a team and cannot have everyone&#8217;s install experience depend on a certificate exception; you need a support contract or procurement paperwork; or your time is worth more than the licence the first time a Code 52 eats an afternoon. <strong>Do not pay if:</strong> the signed package installs on your machine (test it first — it takes five minutes and settles the question); you are a home-lab or hobby user; or you specifically want a scriptable, open-source driver whose behaviour you can read in the source. Also do not pay expecting better pair performance — that is not what is for sale.</p>
<h2>Switching costs, coexistence and the dormancy factor</h2>
<p>People rarely ask whether the two tools can live on one machine. Mostly, yes — but treat it as a migration, not a marriage. Both drivers create ports with ordinary COM names, and a name can only belong to one port at a time: if com0com owns COM10/COM11 for a linked pair of programs and you want Eltima to serve the same two programs, remove the com0com pair first (the clean procedure is in <a href="/uninstall-com0com/">uninstalling com0com</a>), then create the equivalent pair in VSPD and point your programs at the same names. Applications neither know nor care which driver manufactures their port — they open COM10 and talk. That indifference is what makes trying com0com first a genuinely free experiment: test the signed package on your machine today; if it loads, the migration question never arises.</p>
<p>The longer view is the dormancy factor. com0com&#8217;s last release is version 3.0.0.0, from June 2012, and the project has been quiet since — its SourceForge page was last updated in 2018. Fourteen years of still working is a testament to how stable the Windows driver model is, and also a statement of risk: when a future Windows release finally changes a rule the driver depends on, nobody will ship a fix. Eltima is a going concern whose product exists precisely to track those rule changes; part of what a licence buys is a vendor whose job is to notice. On a personal machine, dormancy is a shrug — the tool works until it doesn&#8217;t, and migration is an afternoon. In an environment where the pair is load-bearing for a team or a process, dormancy is a line item in the risk column, and it belongs in this comparison alongside the signature: you are not only buying today&#8217;s install, you are buying the existence of a tomorrow.</p>
<p>There is also an assurance asymmetry worth naming. com0com&#8217;s source code is published under GPLv2: a sufficiently motivated engineer can read exactly what the driver does and audit it. VSPD is proprietary; your assurance is the vendor&#8217;s signature, reputation and support organisation rather than inspectability. Which of those two assurances your environment prefers is a cultural question as much as a technical one — open-source shops and regulated shops answer it in opposite directions, and both answers are defensible.</p>
<h2>Verdict</h2>
<p>com0com is the better driver story; Eltima is the better <em>procurement</em> story. On a machine that accepts it, com0com wins at $0 and it is not close. On a machine that refuses it, no amount of preference changes the arithmetic, and VSPD is the standard, properly-signed way through. If you have reached that point, the vendor&#8217;s page is here: <a href="/go/eltima-vspd" rel="sponsored nofollow">Eltima Virtual Serial Port Driver</a> (sponsored). If you have not reached it yet, go and try the free install first — <a href="/download/">the packages and checksums are on the download page</a> — and let your own machine cast the deciding vote.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/com0com-vs-eltima-vspd/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>com0com Alternatives: 8 Virtual Serial Port Tools Compared</title>
		<link>https://com0com.com/com0com-alternatives/</link>
					<comments>https://com0com.com/com0com-alternatives/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 01:00:00 +0000</pubDate>
				<category><![CDATA[Comparisons & Buying]]></category>
		<guid isPermaLink="false">https://com0com.com/com0com-alternatives/</guid>

					<description><![CDATA[com0com is the best free virtual serial port driver ever released for Windows — and people still go looking for alternatives every day. Almost never because of features. They leave because of one thing: driver signing. com0com&#8217;s driver is test-signed, the community signed package on SourceForge relies on a legacy cross-signed certificate from CyberCircuits, and...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">com0com is the best free virtual serial port driver ever released for Windows — and people still go looking for alternatives every day. Almost never because of features. They leave because of one thing: <strong>driver signing</strong>. com0com&#8217;s driver is test-signed, the community signed package on SourceForge relies on a legacy cross-signed certificate from CyberCircuits, and on a growing number of Windows 11 machines — especially with Secure Boot and memory integrity on — that story ends in a <a href="/fix-com0com-code-52/">Code 52 error</a>. If that is your situation, this page is the honest map of where to go next.</p>
<p><strong>The short verdict:</strong> if the com0com signed package installs on your machine, you do not need an alternative — nothing paid creates port pairs better. If it does not install and the machine is locked down, you are not buying features, you are buying a proper Microsoft signature, and that means Eltima VSPD first. If your real problem is splitting one physical port between several programs, that is VSPE&#8217;s home turf (or the free com0com + hub4com route). If you need a COM port reachable over the network, that is a different product category entirely. Everything below expands on those four sentences.</p>
<h2>Why people actually replace com0com</h2>
<p>It helps to be precise about the failure, because each alternative fixes a different one:</p>
<ul>
<li><strong>Code 52 / error 577 on Windows 11.</strong> The driver will not load. The free fixes (signed package, then Test Mode) are covered on the <a href="/download/">download page</a> — but Test Mode means deliberately weakening your machine&#8217;s driver-signing enforcement, and on work machines it is usually forbidden outright.</li>
<li><strong>&#8220;I need one port in three programs.&#8221;</strong> com0com creates pairs; it does not split a physical port. Splitting is hub4com&#8217;s job in the free world, or a built-in feature in VSPE.</li>
<li><strong>&#8220;The port has to be on another machine.&#8221;</strong> Pairs live inside one PC. Ports over a network need a redirector (software) or a serial device server (hardware).</li>
<li><strong>&#8220;I need someone to call.&#8221;</strong> com0com has been dormant since version 3.0.0.0 in 2012. There is no vendor, no support desk, no roadmap. Some workplaces cannot run tools like that, whatever the license says.</li>
</ul>
<h2>The alternatives, one by one</h2>
<h2>Eltima Virtual Serial Port Driver — the signed escape hatch</h2>
<p><strong>Price: $89.95 (Standard) / $199.95 (Pro), 14-day trial. Prices as of October 2026 — check the vendor site before buying.</strong> Eltima&#8217;s VSPD is the alternative most com0com refugees end up with, for one reason: its driver carries a proper Microsoft signature, so it installs on Windows 11 machines — Secure Boot, memory integrity, corporate policy and all — with none of the Test Mode dance. It creates virtual port pairs with a polished settings GUI, and there is a company behind it that answers email. You are paying for the signature, the interface and the support, in that order. If your machine accepts the free signed package, none of those three is worth $89.95 to you; if it does not, this is the shortest path back to work: <a href="/go/eltima-vspd" rel="sponsored nofollow">Eltima Virtual Serial Port Driver</a> (sponsored). The full head-to-head is in <a href="/com0com-vs-eltima-vspd/">com0com vs Eltima VSPD</a>.</p>
<h2>VSPE (Eterlogic) — the splitter&#8217;s favourite</h2>
<p><strong>Price: $49.95; the 32-bit version is free.</strong> VSPE is less a pair driver than a serial port toolbox: it creates pairs, yes, but its party tricks are splitting one physical port so several programs can read it, joining ports, and mapping a port to TCP. If your problem statement contains the word &#8220;share&#8221;, VSPE is probably your answer — the free equivalent is com0com plus hub4com, which works but is noticeably more spartan. Note the pricing tell: 32-bit is free and 64-bit costs money, because properly signing a 64-bit Windows driver is exactly what costs vendors money. Same economics as com0com&#8217;s signing problem, solved by charging you. Detailed comparison: <a href="/com0com-vs-vspe/">com0com vs VSPE</a>.</p>
<h2>FabulaTech Virtual Serial Port Kit — the other commercial pair driver</h2>
<p><strong>Price: $129.95 (as of October 2026).</strong> FabulaTech&#8217;s kit creates virtual serial port pairs at driver level and has been sold to the industrial and development market for years. It does the core job — pairs that behave like real ports — with a commercial license and vendor support. It sits between Eltima&#8217;s two tiers on price without a standout feature story for a typical com0com user, which is why it is usually the second or third commercial option people evaluate rather than the first.</p>
<h2>AGG Virtual Null Modem — the budget pair driver</h2>
<p><strong>Price: $35 (as of October 2026).</strong> AGG&#8217;s Virtual Null Modem does one thing — virtual null-modem pairs — at the lowest price of any commercial tool on this page. If you have established that you must pay (your machine rejects com0com and policy forbids Test Mode) but your need is genuinely just pairs, $35 is the cheapest legitimate way out of the signing problem. The trade is a smaller vendor and a narrower tool than Eltima&#8217;s.</p>
<h2>HHD Free Virtual Serial Port — the other free one</h2>
<p><strong>Price: $0 for the free edition; the paid edition is $89.99 (as of October 2026).</strong> HHD Software&#8217;s free tool creates a virtual pair for testing serial applications, and it is the alternative most often suggested when people ask &#8220;is there anything else free?&#8221; Two honest caveats: a free edition of a commercial product is a funnel, so expect prompts toward the paid tier; and before relying on any free driver on a modern Windows install, check whose signature it carries — that is the same question that decides com0com&#8217;s fate on your machine. Worth trying, costs nothing but time.</p>
<h2>HW VSP3 — not a pair driver (and that&#8217;s fine)</h2>
<p><strong>Price: free, single port.</strong> HW VSP3 is a virtual COM port that redirects to a device on your network over TCP — a COM-to-network redirector, not a null-modem pair emulator. People land on it while searching for pair tools and bounce off confused. If your actual goal is &#8220;this program must talk to a serial device that lives elsewhere on the LAN&#8221;, VSP3 is genuinely useful and free for one port; note the product is in run-out, so treat it as a handy legacy utility, not a platform to build on. Our <a href="/rfc2217-server-client/">RFC 2217 recipes</a> cover the free com0com-side route to the same territory.</p>
<h2>VSP Manager — free, if you&#8217;re a licensed ham</h2>
<p><strong>Price: free for licensed amateur radio operators.</strong> In the ham radio world, where one rig port must feed logging, digital-mode and rig-control software simultaneously, VSP Manager is a long-standing favourite and is free to licensed hams. Everyone else should read it as a signpost: the ham community solved the port-sharing problem years ago, and the tools above are how. More in our <a href="/ham-radio-virtual-com-ports/">ham radio virtual COM ports</a> guide.</p>
<h2>socat — the Linux answer, in one line</h2>
<p>On Linux you never needed com0com: socat creates linked pseudo-terminal pairs natively. Mentioned only so nobody goes hunting for &#8220;com0com for Linux&#8221;.</p>
<h2>Which one, by situation</h2>
<table>
<thead><tr><th>Your situation</th><th>Reach for</th><th>Why</th></tr></thead>
<tbody>
<tr><td>com0com&#8217;s signed package installs fine</td><td>com0com (free)</td><td>Nothing paid creates pairs better; you already have the good driver</td></tr>
<tr><td>Code 52, work or Secure Boot machine, Test Mode forbidden</td><td>Eltima VSPD ($89.95+)</td><td>Proper Microsoft signature is the product you are buying</td></tr>
<tr><td>Code 52, personal machine, budget is firm</td><td>AGG Virtual Null Modem ($35) or Test Mode (free)</td><td>Cheapest legitimate signature, or the free workaround with eyes open</td></tr>
<tr><td>Split one physical port into many programs</td><td>VSPE ($49.95) or com0com + hub4com (free)</td><td>Splitting is VSPE&#8217;s headline feature; hub4com does it free, more spartan — see <a href="/split-serial-port/">splitting a serial port</a></td></tr>
<tr><td>COM port must live on the network</td><td>HW VSP3 (free, 1 port) or a serial device server (hardware)</td><td>Different category: redirector or hardware, not a pair driver</td></tr>
<tr><td>Ham station, one rig port, many programs</td><td>VSP Manager (free for licensed hams) or VSPE</td><td>The community-standard tools for exactly this contention</td></tr>
<tr><td>Linux</td><td>socat</td><td>Built for it; no driver drama at all</td></tr>
</tbody>
</table>
<h2>The honest bottom line</h2>
<p>&#8220;Alternative&#8221; lists usually pretend the paid tools are faster or more capable. For plain port pairs, they are not — com0com&#8217;s kernel pairs are the reference implementation a generation of developers tested against, and a 4.4/5 rating from 64 SourceForge reviews reflects real, long use. What money buys in this category is <em>permission</em>: a signature Windows trusts without workarounds, a GUI instead of command lines, and a vendor who still exists. Buy exactly the permission you need, and not a dollar more. If you are still deciding, work the free path first — <a href="/install-com0com-windows-11/">install com0com on Windows 11</a> — and only spend when a machine or a policy tells you no. For the same field ranked as buyer&rsquo;s picks by job &mdash; pairs, signing, splitting and networking &mdash; see our <a href="/best-virtual-serial-port-software/">best virtual serial port software</a> guide.</p>