Here is a failure that wastes hours because everything looks healthy: com0com is installed, Device Manager is happy, the pair exists — and your application opens its port selection dropdown and shows nothing. No error, no entry, no clue. In almost every case the driver is fine and the pair is fine. The problem is the ports’ names. By default com0com ports are called CNCA0 and CNCB0, and a large share of serial software simply never looks for names like that.
Why applications cannot see CNCA0 and CNCB0
Real serial ports live in the Windows Ports class and carry standard names — COM1, COM3, COM10 and so on. Most applications build their port list by enumerating exactly that class, or by scanning a range of COM names and testing which ones answer. Legacy software is stricter still: many older programs only scan the low numbers they were written for, and some very old tools hard-code a short list like COM1–COM4. A com0com port under its default name is a perfectly functional device that simply is not registered under a COM-style name, so these enumerations pass straight over it. The port is not missing; it is invisible to the way your application looks.
You can confirm the pair itself exists before changing anything. Open the Setup Command Prompt as administrator and run:
command> list
If your pair is listed (typically as CNCA0 ↔ CNCB0), the driver side of the story is closed and the rest of this page is the fix.
The fix: rename the ports into the Ports class
com0com supports giving a port a real COM name by setting its PortName to a COM# value, which places the port in the Ports class where applications enumerate it. You can do it in SetupG (select the port, enable the standard-name option and choose the number) or from setupc — the exact, verified procedure is our guide to renaming a com0com port, and it takes two minutes. Two pieces of advice specific to this problem:
- Pick numbers your application actually scans. If the software is old, choose low, currently free numbers such as COM3 or COM4 rather than COM27 — many legacy enumerations stop early. Check which numbers are taken in Device Manager (View → Show hidden devices reveals greyed reservations) before choosing.
- Rename both ends deliberately. Your application uses one end of the pair; whatever feeds it (a simulator, a second program, a terminal) uses the other. Give each end the name its own program expects, and write the mapping down — CNCA0 → COM5, CNCB0 → COM6 — before you forget which is which.
After renaming, restart the application completely — many programs build their port list once at startup and will not notice a new port while running. Then check the dropdown again. For most readers, the story ends here.
Verify the renamed port really works
A name in a list is not proof of a working path, so test the pair before blaming the application further. Open a terminal program on one end (any serial terminal will do) and your application — or a second terminal — on the other, type in one window, and confirm the characters arrive in the other. Our first-pair walkthrough includes this two-window loopback test step by step. If data flows between two terminals but your specific application still fails, the problem has narrowed to that application’s expectations, which is what the next section is for.
If the port still does not show up
- The application caches its port list. Restart it after every rename. Some tools only enumerate ports at install time or first run; a reboot is the blunt version of the same fix.
- The application scans a fixed low range. Rename to the lowest free COM number you can. This is the single most common resolution for industrial and hobby software written for physical COM1/COM2 machines.
- The application accepts a typed device path. Some programs let you enter a port name manually even when it is not listed. If yours does, the com0com device can often be opened under its device path form (
\\.\CNCA0) even without renaming — worth one attempt before deeper surgery. - The partner end is already open. A serial port is normally opened exclusively. If another program is holding the other end of the pair (or the same end), your application may fail to open the port or behave as if it is not there. Close stray terminals and simulator processes and try again.
- 32-bit application on 64-bit Windows. The port naming rules above apply equally; a 32-bit application uses the same Ports-class enumeration. Very old programs that talk to hardware through outdated interfaces may never see any software port — com0com or otherwise — and for those, the realistic answer is a physical port. That is a limitation of the application, not of your pair.
Check what Windows itself sees
After renaming, look in Device Manager under Ports (COM & LPT): your ports should now appear there under their COM names — that listing is exactly what well-behaved applications enumerate. If the port still appears only under its CNCA/CNCB name, the rename did not take effect (re-run it, and reboot — port identity changes settle at boot more often than the tools admit). If the port appears under Ports with the right name but the application still shows nothing, the application’s list is the outlier, and the workarounds in the next section are aimed at it rather than at Windows. It is also worth confirming both ends of the pair are listed: rename and application must agree about which end is which, and a one-ended success — your app sees COM5, but nothing is feeding COM5’s partner — presents as a port that opens and stays silent. Feed the partner end with a terminal, send a few characters, and watch them arrive before concluding anything about the application.
A related trap: ports above COM9
If you rename a port to a two-digit number — COM10 and above — some older applications still cannot open it even though it is properly listed. The reason is an old Windows naming rule: the classic file APIs these programs use need the device-path form \\.\COM10 for two-digit port names, while COM1–COM9 work in the plain form. Applications written before virtual ports made high numbers common often lack that handling entirely. This is the deeper reason behind this page’s earlier advice to prefer low numbers for legacy software: a port named COM4 sidesteps both the scanning-range problem and the two-digit path problem in one move. If your application lets you type a full device path, entering the \\.\ form for its configured port is worth one attempt before concluding the software cannot use the pair at all.
The short version
Driver fine + pair listed in setupc list + application dropdown empty = a naming problem until proven otherwise. Rename into the Ports class with low free COM numbers, restart the application, and prove the path with a loopback test. If the pair itself is not even listed, you are one step earlier in the chain — start from the install guide or, after an update broke things, the post-update recovery. And if the port opens but data stalls or comes back stale, that is a different known behaviour with its own fix: hangs and buffer overrun.
