<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Guides &#8211; com0com</title>
	<atom:link href="https://com0com.com/guides/feed/" rel="self" type="application/rss+xml" />
	<link>https://com0com.com</link>
	<description>Virtual Serial Port Driver for Windows 11/10</description>
	<lastBuildDate>Wed, 21 Oct 2026 09:45:50 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://com0com.com/wp-content/uploads/2026/04/favicon-150x150.png</url>
	<title>Guides &#8211; com0com</title>
	<link>https://com0com.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>com0com on Windows 10 (64-Bit): Installation and Signing Guide</title>
		<link>https://com0com.com/com0com-windows-10/</link>
					<comments>https://com0com.com/com0com-windows-10/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 07:00:00 +0000</pubDate>
				<category><![CDATA[Guides]]></category>
		<guid isPermaLink="false">https://com0com.com/?p=551</guid>

					<description><![CDATA[com0com on Windows 10 sits in an awkward middle ground: the same 3.0.0.0 driver and the same signed package as Windows 11, but a signing landscape that changed halfway through Windows 10&#8217;s own life. Whether the driver loads on your Windows 10 PC depends on which side of the Windows 10 version 1607 policy change...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">com0com on Windows 10 sits in an awkward middle ground: the same 3.0.0.0 driver and the same signed package as Windows 11, but a signing landscape that changed halfway through Windows 10&#8217;s own life. Whether the driver loads on your Windows 10 PC depends on which side of the Windows 10 version 1607 policy change your installation effectively falls — and on Secure Boot. This guide explains the Windows 10 specifics, how they differ from Windows 11, and what to do in each case.</p>



<p class="wp-block-paragraph">New to com0com entirely? It is the free, GPLv2 null-modem emulator by Vyacheslav Frolov: a kernel-mode driver that creates virtual COM port pairs so two applications can exchange serial data without hardware. The packages, checksums and mirrors are on the <a href="/download/">download page</a>; the rest of this guide assumes that is where you got the files.</p>



<h2 class="wp-block-heading">The one thing to understand: the 1607 divide</h2>



<p class="wp-block-paragraph">Before Windows 10 version 1607 (2016), a kernel driver signed with a recognised cross-signing certificate loaded normally. From 1607 onwards, <em>new installations</em> of Windows 10 only load kernel drivers signed through Microsoft&#8217;s Dev Portal — with exceptions. Cross-signed drivers can still load when, among other cases, the certificate was issued before 29 July 2015, or the PC was <em>upgraded</em> from an earlier Windows version rather than freshly installed, or Secure Boot is off. com0com&#8217;s signed package uses a legacy cross-signed certificate (publisher: CyberCircuits) from before that 2015 cut-off, which is why it still loads on many real-world Windows 10 machines — especially long-lived, upgraded installations — and fails with Code 52 on others, typically fresh installs with Secure Boot on.</p>



<p class="wp-block-paragraph">Practical translation: two identical-looking Windows 10 PCs can give you opposite results, and both results are &#8220;normal&#8221;. Do not copy a stranger&#8217;s success or failure as a prediction for your machine — just try the signed package and read the outcome. This is also why forum advice about com0com on Windows 10 contradicts itself so cheerfully: almost everyone is reporting the truth about one machine and one install history.</p>



<h2 class="wp-block-heading">Installing on Windows 10 (64-bit)</h2>



<ol class="wp-block-list">
<li>Download <strong>com0com-3.0.0.0-i386-and-x64-signed.zip</strong> from the <a href="/download/">download page</a> and verify the SHA-256 shown there with <code>Get-FileHash</code> in PowerShell.</li>



<li>Extract it and run <strong>Setup_com0com_v3.0.0.0_W7_x64_signed.exe</strong> as administrator. Yes, the name says W7 — the installers were packaged in the Windows 7 era, and this signed 3.0.0.0 package is the newest that exists. The x86 installer is only for the rare 32-bit Windows 10.</li>



<li>Approve the Windows Security prompt for the publisher <strong>CyberCircuits</strong> if it appears — that is the expected signer of this package.</li>



<li>Check Device Manager: a good install shows the com0com emulator and the default CNCA0/CNCB0 pair with no warning icon. A yellow icon with <em>Code 52</em> in the properties means Windows rejected the signature — continue to the Test Mode section.</li>



<li>Create and rename your ports: the <a href="/create-virtual-com-port-pair/">first-pair walkthrough</a> and the <a href="/rename-com0com-port/">renaming guide</a> apply unchanged on Windows 10.</li>
</ol>



<h2 class="wp-block-heading">Test Mode on Windows 10</h2>



<p class="wp-block-paragraph">If the signed package is rejected, the project&#8217;s own documented answer is test signing: the official ReadMe states that the driver is test-signed, that the x64 build will not load by default, and that you enable test signing by running, from an elevated command prompt:</p>



<pre class="wp-block-code"><code>bcdedit -set TESTSIGNING ON</code></pre>



<p class="wp-block-paragraph">…then rebooting and installing (the unsigned package works under test signing too). Windows shows a &#8220;Test Mode&#8221; watermark on the desktop while the setting is on — that watermark <em>is</em> the setting being active, not a separate fault, and turning test signing off with <code>bcdedit -set TESTSIGNING OFF</code> and a reboot makes the watermark disappear <em>and</em> stops the test-signed driver from loading. There is no supported way to keep the driver and lose the watermark. Two honest cautions, both straight from the project&#8217;s own documentation and Microsoft&#8217;s policy: the ReadMe itself warns that enabling test signing impairs your computer&#8217;s security, and on Secure Boot machines Windows may refuse to change the setting at all, because Secure Boot policy protects it. The <a href="/faq/">FAQ</a> expands on both points.</p>



<h2 class="wp-block-heading">Windows 10 vs Windows 11: what actually differs</h2>



<ul class="wp-block-list">
<li><strong>Same driver, same package.</strong> Nothing about com0com differs between the two systems; every difference below is Windows policy and defaults, not com0com.</li>



<li><strong>More upgraded installs.</strong> A large share of Windows 10 machines arrived as upgrades from Windows 7 or 8.1, or were installed before later policy tightening — situations where the legacy cross-signed package is more likely to load directly.</li>



<li><strong>Secure Boot and Memory Integrity are less uniformly on.</strong> Newer Windows 11 PCs ship with Secure Boot and HVCI (Memory Integrity) enabled far more consistently, and HVCI gives old drivers a second reason to be refused. On Windows 10, Memory Integrity is worth checking manually in Windows Security if a signed install fails for no obvious reason.</li>



<li><strong>Same endgame.</strong> On a locked-down installation of either system — Secure Boot enforced, test signing blocked, policy managed — com0com cannot load, and a commercially Microsoft-signed tool is the realistic route. The comparison lives in the <a href="/virtual-serial-port/">virtual serial port guide</a>; the Windows-11-specific walkthrough, whose steps otherwise mirror this one, is the <a href="/install-com0com-windows-11/">Windows 11 installation guide</a>.</li>
</ul>



<h2 class="wp-block-heading">After a major Windows 10 feature update</h2>



<p class="wp-block-paragraph">One Windows 10 pattern is worth knowing in advance: the big twice-a-year feature updates of the Windows 10 era effectively reinstall Windows underneath your drivers. Occasionally a com0com installation that loaded happily for a year comes back from such an update with its pairs missing or a fresh Code 52. Nothing about com0com changed — the machine simply moved, policy-wise, closer to a fresh install. The recovery is boring and reliable: verify the driver state in Device Manager, reinstall the signed 3.0.0.0 package over the top (your pair configuration is normally preserved; <code>list</code> in <a href="/setupc-commands/">setupc</a> shows what survived), and, if the signature is now refused, use Test Mode as described above. Re-check your COM names afterwards with the <a href="/rename-com0com-port/">renaming guide</a>, because re-registration is exactly the moment a name can revert to CNCA/CNCB defaults.</p>



<h2 class="wp-block-heading">Upgrading from com0com 2.2.2.0</h2>



<p class="wp-block-paragraph">Plenty of Windows 10 test benches still run 2.2.2.0, the 2009 release. Upgrading to 3.0.0.0 is worth it for one feature alone: 3.0.0.0 introduced putting a port into the Windows Ports class via <code>PortName=COM#</code>, which is what makes virtual ports discoverable by ordinary applications. Do the upgrade cleanly rather than over the top:</p>



<ol class="wp-block-list">
<li>Note your existing pair names and settings (the <a href="/setupc-commands/">setupc</a> <code>list</code> command prints them).</li>



<li>Remove the old pairs and uninstall the old driver before installing 3.0.0.0, so no stale port registrations linger.</li>



<li>Install the signed 3.0.0.0 package as above, recreate your pairs, and re-apply your COM names.</li>



<li>If a COM number you used before now shows as taken by an invisible device, that is a leftover &#8220;ghost&#8221; reservation from the old install — the <a href="/faq/">FAQ</a> explains the short version, and picking a fresh number is always a valid workaround for virtual pairs.</li>
</ol>



<p class="wp-block-paragraph">That is the whole Windows 10 picture: try the signed package first, fall back to Test Mode with your eyes open about its security note and watermark, and do not waste hours hunting for &#8220;Windows 10 editions&#8221; of com0com offered elsewhere — there is only the one 3.0.0.0, shared by both systems. More practical walkthroughs, from first pair creation to final cleanup, are collected together in the <a href="/guides/">Guides archive</a>. If your reason for working through these steps is an old serial program you cannot replace, our guide to <a href="/legacy-serial-software-windows-11/">running legacy serial software on Windows 11</a> covers keeping that software working after an upgrade.</p>

]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/com0com-windows-10/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>com0com Version History: 1.0.0.0 to 3.0.0.0 (and Why There Is No 2026 Version)</title>
		<link>https://com0com.com/com0com-version-history/</link>
					<comments>https://com0com.com/com0com-version-history/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 06:00:00 +0000</pubDate>
				<category><![CDATA[Guides]]></category>
		<guid isPermaLink="false">https://com0com.com/?p=550</guid>

					<description><![CDATA[Search for com0com today and you will find sites offering a &#8220;com0com 2026 edition&#8221;, a &#8220;Windows 11 update&#8221;, or version numbers that sound newer than 3.0.0.0. None of them exist. This page is the project&#8217;s real version history, taken from the official SourceForge releases and change logs — including the part most download sites skip:...]]></description>
										<content:encoded><![CDATA[
<ul class="wp-block-list">
<li><strong>hub4com 2.1.0.0 — 18 June 2012.</strong> The latest hub4com, released days after com0com 3.0.0.0. hub4com shares, joins and redirects serial and TCP ports — and it, not the com0com driver, is what provides RFC 2217 support.</li>



<li><strong>com2tcp 1.3.0.0 — 7 May 2007.</strong> The last standalone release of the COM-to-TCP redirector. Its functionality was absorbed into hub4com from hub4com 2.0.0.0 onwards (the <code>com2tcp.bat</code> shipped with hub4com is a wrapper around it), which is why there has been no com2tcp release since 2007 — it was superseded, not abandoned mid-stream.</li>
</ul>


<h2 class="wp-block-heading">&#8220;Is there a 2026 version?&#8221; No — and why that matters</h2>



<p class="wp-block-paragraph">There is no 2026 version of com0com, no 2025 version, and no version of any kind after 3.0.0.0 from June 2012. The project is dormant. When a site advertises a &#8220;com0com 2026&#8221; download, one of two things is true: it is the genuine 2012 package with a new label, or it is a modified build from an unverifiable source. For a <em>kernel-mode driver</em> — code that runs at the deepest privilege level of your operating system — the second possibility is a genuine security risk, and the first is simply dishonest. This site removed a third-party &#8220;patch&#8221; build from its own download page for exactly that reason: its origin and signing chain could not be verified.</p>



<p class="wp-block-paragraph">The dormancy also explains the Windows 11 situation without any conspiracy. The driver is test-signed, as its own ReadMe states. The signed package relies on a cross-signing certificate from before Microsoft&#8217;s 29 July 2015 policy cut-off. Microsoft has steadily tightened kernel-driver signing since Windows 10 version 1607 — so a package that loaded everywhere in 2017 loads on many PCs today and returns Code 52 on others, particularly with Secure Boot and Memory Integrity enforced. Nothing about com0com changed; the ground moved under it. The <a href="/install-com0com-windows-11/">installation guide</a> explains what to do in each case, honestly.</p>



<h2 class="wp-block-heading">Which version should you actually use?</h2>



<ul class="wp-block-list">
<li><strong>Use 3.0.0.0, signed package.</strong> It is the newest release, it has the Ports-class renaming feature everything on this site relies on, and its SHA-256 can be verified against SourceForge. The unsigned 3.0.0.0 package (2012) is the fallback for test-signing setups.</li>



<li><strong>Treat 2.2.2.0 as archaeology.</strong> It is occasionally useful for understanding an ancient installation you have inherited, but it predates the Ports-class feature and gains you nothing on a modern machine. If you are upgrading from it, remove the old pairs and driver first — see the <a href="/com0com-windows-10/">Windows 10 guide</a> for the upgrade notes.</li>



<li><strong>The source code is available.</strong> The project is GPLv2, and the 3.0.0.0 source package sits on SourceForge next to the binaries. The licence permits use for any purpose, including commercial use, under its conditions — a property of the GPLv2 itself, as the <a href="/faq/">FAQ</a> explains. Whether anyone will ever maintain a fork to a signed 4.0 is an open question; as of October 2026, no SourceForge or otherwise official successor exists.</li>
</ul>


<p class="wp-block-paragraph">So the honest summary is short: one driver, finished in 2012, still uniquely useful, increasingly awkward for Windows to accept. That is not a reason to avoid it — for a free GPLv2 tool with an effectively unlimited pair count and two decades of accumulated know-how in forums, it remains the default answer to &#8220;I need two programs to talk over a serial link&#8221;. It is simply a reason to install it with your eyes open, from the official package, knowing exactly which version you have and why Windows treats it the way it does.</p>
 Everything else on this site — the <a href="/guides/">guides</a>, the signing explanations, the workarounds — exists to help you run that real 3.0.0.0 well, rather than to pretend a newer one exists.</p>

<!-- /wp:list -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>1.0.0.0 — 21 February 2005.</strong> The first public release of the Null-modem emulator by Vyacheslav Frolov, published on SourceForge. A kernel-mode driver that creates virtual COM port pairs, at a time when that meant Windows 2000 and XP.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>2.0.0.0 — 4 December 2007.</strong> The release that added support for 64-bit systems and introduced the graphical setup utility, setupg.exe — the <a href="/setupg-guide/">SetupG</a> still in use today. The 2.x line continued through 2.1.0.0 and 2.2.1.0.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>2.2.2.0 — 17 December 2009.</strong> The final 2.x release. Its packages included a signed 64-bit build (the x64-fre-signed package) — an early answer to the driver-signing requirements that would come to dominate this project&#8217;s story.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>3.0.0.0 — 4 June 2012.</strong> The current and final version. Its headline change, per the official Changes.txt, was the ability to put a port into the Windows <strong>Ports class</strong> — the <code>PortName=COM#</code> mechanism that lets you give a virtual port a standard COM name applications can discover, covered in the <a href="/rename-com0com-port/">renaming guide</a>. The release was announced by Frolov on 14 June 2012.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Signed package uploaded — 13 July 2017.</strong> Not a new version. The same 3.0.0.0 was uploaded to SourceForge as <code>com0com-3.0.0.0-i386-and-x64-signed.zip</code>, containing installers signed with a legacy cross-signing certificate (publisher: CyberCircuits). This is the package our <a href="/download/">download page</a> links to, checksum and all.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>2018 onwards — dormancy.</strong> The SourceForge project page was last updated on 9 April 2018. A ticket opened in 2018 asking for properly signed drivers for modern Windows (ticket #32) is still open and unassigned. The author has made no further releases.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">The 1.x years: where the emulation features came from</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The headline releases above are not the whole story. The official Changes.txt records the smaller 1.x versions quietly adding the features everything since has relied on: <strong>baud rate emulation arrived in 1.3.0.0</strong> and was improved in 1.8.0.0 (June 2007), and <strong>overrun emulation was implemented in 1.4.0.0</strong>. In other words, the testing behaviours that make com0com useful to developers — realistic pacing, dropped bytes, later noise emulation — were all in place by 2007. The 2.x and 3.0.0.0 releases were mostly about platform reach (64-bit support, the Ports class) rather than new emulation tricks. When you use EmuBR or EmuOverrun today, you are using some of the oldest, most battle-tested code in the package.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">How to tell which version you have</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Inherited a machine and not sure what is installed? Three quick checks. First, the installer and zip filenames carry the version: anything named <code>…v3.0.0.0…</code> or <code>com0com-3.0.0.0-…</code> is the final release, while <code>2.2.2.0</code> in a filename marks the 2009 build. Second, the package&#8217;s ReadMe.txt, installed with the driver and also published in the project&#8217;s file area, documents the version it belongs to. Third — the feature test: if you can assign a port a standard COM name with <code>PortName=COM#</code> (see the <a href="/setupc-commands/">setupc reference</a>), you are on 3.0.0.0, because that Ports-class capability did not exist before it. If your installation turns out to be 2.2.2.0, the <a href="/com0com-windows-10/">Windows 10 guide</a> includes clean upgrade notes.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">The companion tools have their own timelines</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>com0com is the driver, but the same SourceForge project hosts two companion tools by the same author, and their histories matter because download sites often present them as current:</p>
<!-- /wp:paragraph -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>hub4com 2.1.0.0 — 18 June 2012.</strong> The latest hub4com, released days after com0com 3.0.0.0. hub4com shares, joins and redirects serial and TCP ports — and it, not the com0com driver, is what provides RFC 2217 support.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>com2tcp 1.3.0.0 — 7 May 2007.</strong> The last standalone release of the COM-to-TCP redirector. Its functionality was absorbed into hub4com from hub4com 2.0.0.0 onwards (the <code>com2tcp.bat</code> shipped with hub4com is a wrapper around it), which is why there has been no com2tcp release since 2007 — it was superseded, not abandoned mid-stream.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">&#8220;Is there a 2026 version?&#8221; No — and why that matters</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>There is no 2026 version of com0com, no 2025 version, and no version of any kind after 3.0.0.0 from June 2012. The project is dormant. When a site advertises a &#8220;com0com 2026&#8221; download, one of two things is true: it is the genuine 2012 package with a new label, or it is a modified build from an unverifiable source. For a <em>kernel-mode driver</em> — code that runs at the deepest privilege level of your operating system — the second possibility is a genuine security risk, and the first is simply dishonest. This site removed a third-party &#8220;patch&#8221; build from its own download page for exactly that reason: its origin and signing chain could not be verified.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The dormancy also explains the Windows 11 situation without any conspiracy. The driver is test-signed, as its own ReadMe states. The signed package relies on a cross-signing certificate from before Microsoft&#8217;s 29 July 2015 policy cut-off. Microsoft has steadily tightened kernel-driver signing since Windows 10 version 1607 — so a package that loaded everywhere in 2017 loads on many PCs today and returns Code 52 on others, particularly with Secure Boot and Memory Integrity enforced. Nothing about com0com changed; the ground moved under it. The <a href="/install-com0com-windows-11/">installation guide</a> explains what to do in each case, honestly.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Which version should you actually use?</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Use 3.0.0.0, signed package.</strong> It is the newest release, it has the Ports-class renaming feature everything on this site relies on, and its SHA-256 can be verified against SourceForge. The unsigned 3.0.0.0 package (2012) is the fallback for test-signing setups.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Treat 2.2.2.0 as archaeology.</strong> It is occasionally useful for understanding an ancient installation you have inherited, but it predates the Ports-class feature and gains you nothing on a modern machine. If you are upgrading from it, remove the old pairs and driver first — see the <a href="/com0com-windows-10/">Windows 10 guide</a> for the upgrade notes.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>The source code is available.</strong> The project is GPLv2, and the 3.0.0.0 source package sits on SourceForge next to the binaries. The licence permits use for any purpose, including commercial use, under its conditions — a property of the GPLv2 itself, as the <a href="/faq/">FAQ</a> explains. Whether anyone will ever maintain a fork to a signed 4.0 is an open question; as of October 2026, no SourceForge or otherwise official successor exists.</li>
<!-- /wp:list-item --></ul>

<!-- wp:paragraph -->
<p>So the honest summary is short: one driver, finished in 2012, still uniquely useful, increasingly awkward for Windows to accept. That is not a reason to avoid it — for a free GPLv2 tool with an effectively unlimited pair count and two decades of accumulated know-how in forums, it remains the default answer to &#8220;I need two programs to talk over a serial link&#8221;. It is simply a reason to install it with your eyes open, from the official package, knowing exactly which version you have and why Windows treats it the way it does.</p>
 Everything else on this site — the <a href="/guides/">guides</a>, the signing explanations, the workarounds — exists to help you run that real 3.0.0.0 well, rather than to pretend a newer one exists.</p>
<!-- /wp:paragraph -->
<!-- /wp:post-content --><!-- /wp:list --><!-- wp:post-content --><!-- wp:paragraph -->
<p>Search for com0com today and you will find sites offering a &#8220;com0com 2026 edition&#8221;, a &#8220;Windows 11 update&#8221;, or version numbers that sound newer than 3.0.0.0. None of them exist. This page is the project&#8217;s real version history, taken from the official SourceForge releases and change logs — including the part most download sites skip: the driver has not changed since 2012, and understanding that one fact explains almost everything about installing and running com0com today.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">The timeline</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>1.0.0.0 — 21 February 2005.</strong> The first public release of the Null-modem emulator by Vyacheslav Frolov, published on SourceForge. A kernel-mode driver that creates virtual COM port pairs, at a time when that meant Windows 2000 and XP.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>2.0.0.0 — 4 December 2007.</strong> The release that added support for 64-bit systems and introduced the graphical setup utility, setupg.exe — the <a href="/setupg-guide/">SetupG</a> still in use today. The 2.x line continued through 2.1.0.0 and 2.2.1.0.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>2.2.2.0 — 17 December 2009.</strong> The final 2.x release. Its packages included a signed 64-bit build (the x64-fre-signed package) — an early answer to the driver-signing requirements that would come to dominate this project&#8217;s story.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>3.0.0.0 — 4 June 2012.</strong> The current and final version. Its headline change, per the official Changes.txt, was the ability to put a port into the Windows <strong>Ports class</strong> — the <code>PortName=COM#</code> mechanism that lets you give a virtual port a standard COM name applications can discover, covered in the <a href="/rename-com0com-port/">renaming guide</a>. The release was announced by Frolov on 14 June 2012.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Signed package uploaded — 13 July 2017.</strong> Not a new version. The same 3.0.0.0 was uploaded to SourceForge as <code>com0com-3.0.0.0-i386-and-x64-signed.zip</code>, containing installers signed with a legacy cross-signing certificate (publisher: CyberCircuits). This is the package our <a href="/download/">download page</a> links to, checksum and all.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>2018 onwards — dormancy.</strong> The SourceForge project page was last updated on 9 April 2018. A ticket opened in 2018 asking for properly signed drivers for modern Windows (ticket #32) is still open and unassigned. The author has made no further releases.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">The 1.x years: where the emulation features came from</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The headline releases above are not the whole story. The official Changes.txt records the smaller 1.x versions quietly adding the features everything since has relied on: <strong>baud rate emulation arrived in 1.3.0.0</strong> and was improved in 1.8.0.0 (June 2007), and <strong>overrun emulation was implemented in 1.4.0.0</strong>. In other words, the testing behaviours that make com0com useful to developers — realistic pacing, dropped bytes, later noise emulation — were all in place by 2007. The 2.x and 3.0.0.0 releases were mostly about platform reach (64-bit support, the Ports class) rather than new emulation tricks. When you use EmuBR or EmuOverrun today, you are using some of the oldest, most battle-tested code in the package.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">How to tell which version you have</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Inherited a machine and not sure what is installed? Three quick checks. First, the installer and zip filenames carry the version: anything named <code>…v3.0.0.0…</code> or <code>com0com-3.0.0.0-…</code> is the final release, while <code>2.2.2.0</code> in a filename marks the 2009 build. Second, the package&#8217;s ReadMe.txt, installed with the driver and also published in the project&#8217;s file area, documents the version it belongs to. Third — the feature test: if you can assign a port a standard COM name with <code>PortName=COM#</code> (see the <a href="/setupc-commands/">setupc reference</a>), you are on 3.0.0.0, because that Ports-class capability did not exist before it. If your installation turns out to be 2.2.2.0, the <a href="/com0com-windows-10/">Windows 10 guide</a> includes clean upgrade notes.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">The companion tools have their own timelines</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>com0com is the driver, but the same SourceForge project hosts two companion tools by the same author, and their histories matter because download sites often present them as current:</p>
<!-- /wp:paragraph -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>hub4com 2.1.0.0 — 18 June 2012.</strong> The latest hub4com, released days after com0com 3.0.0.0. hub4com shares, joins and redirects serial and TCP ports — and it, not the com0com driver, is what provides RFC 2217 support.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>com2tcp 1.3.0.0 — 7 May 2007.</strong> The last standalone release of the COM-to-TCP redirector. Its functionality was absorbed into hub4com from hub4com 2.0.0.0 onwards (the <code>com2tcp.bat</code> shipped with hub4com is a wrapper around it), which is why there has been no com2tcp release since 2007 — it was superseded, not abandoned mid-stream.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">&#8220;Is there a 2026 version?&#8221; No — and why that matters</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>There is no 2026 version of com0com, no 2025 version, and no version of any kind after 3.0.0.0 from June 2012. The project is dormant. When a site advertises a &#8220;com0com 2026&#8221; download, one of two things is true: it is the genuine 2012 package with a new label, or it is a modified build from an unverifiable source. For a <em>kernel-mode driver</em> — code that runs at the deepest privilege level of your operating system — the second possibility is a genuine security risk, and the first is simply dishonest. This site removed a third-party &#8220;patch&#8221; build from its own download page for exactly that reason: its origin and signing chain could not be verified.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The dormancy also explains the Windows 11 situation without any conspiracy. The driver is test-signed, as its own ReadMe states. The signed package relies on a cross-signing certificate from before Microsoft&#8217;s 29 July 2015 policy cut-off. Microsoft has steadily tightened kernel-driver signing since Windows 10 version 1607 — so a package that loaded everywhere in 2017 loads on many PCs today and returns Code 52 on others, particularly with Secure Boot and Memory Integrity enforced. Nothing about com0com changed; the ground moved under it. The <a href="/install-com0com-windows-11/">installation guide</a> explains what to do in each case, honestly.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Which version should you actually use?</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Use 3.0.0.0, signed package.</strong> It is the newest release, it has the Ports-class renaming feature everything on this site relies on, and its SHA-256 can be verified against SourceForge. The unsigned 3.0.0.0 package (2012) is the fallback for test-signing setups.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Treat 2.2.2.0 as archaeology.</strong> It is occasionally useful for understanding an ancient installation you have inherited, but it predates the Ports-class feature and gains you nothing on a modern machine. If you are upgrading from it, remove the old pairs and driver first — see the <a href="/com0com-windows-10/">Windows 10 guide</a> for the upgrade notes.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>The source code is available.</strong> The project is GPLv2, and the 3.0.0.0 source package sits on SourceForge next to the binaries. The licence permits use for any purpose, including commercial use, under its conditions — a property of the GPLv2 itself, as the <a href="/faq/">FAQ</a> explains. Whether anyone will ever maintain a fork to a signed 4.0 is an open question; as of October 2026, no SourceForge or otherwise official successor exists.</li>
<!-- /wp:list-item --></ul>

<!-- wp:paragraph -->
<p>So the honest summary is short: one driver, finished in 2012, still uniquely useful, increasingly awkward for Windows to accept. That is not a reason to avoid it — for a free GPLv2 tool with an effectively unlimited pair count and two decades of accumulated know-how in forums, it remains the default answer to &#8220;I need two programs to talk over a serial link&#8221;. It is simply a reason to install it with your eyes open, from the official package, knowing exactly which version you have and why Windows treats it the way it does.</p>
 Everything else on this site — the <a href="/guides/">guides</a>, the signing explanations, the workarounds — exists to help you run that real 3.0.0.0 well, rather than to pretend a newer one exists.</p>
<!-- /wp:paragraph -->
<!-- /wp:post-content -->]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/com0com-version-history/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>setupc.exe Commands: The com0com Command-Line Reference</title>
		<link>https://com0com.com/setupc-commands/</link>
					<comments>https://com0com.com/setupc-commands/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 05:00:00 +0000</pubDate>
				<category><![CDATA[Guides]]></category>
		<guid isPermaLink="false">https://com0com.com/?p=549</guid>

					<description><![CDATA[setupc.exe — the Setup Command Prompt — is com0com&#8217;s command-line configuration tool, installed together with the driver. It does everything the graphical SetupG does, from a console: create and remove pairs, rename ports, switch emulation options, and list the current configuration. That makes it the right tool for scripting a repeatable setup, working over a...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">setupc.exe — the Setup Command Prompt — is com0com&#8217;s command-line configuration tool, installed together with the driver. It does everything the graphical <a href="/setupg-guide/">SetupG</a> does, from a console: create and remove pairs, rename ports, switch emulation options, and list the current configuration. That makes it the right tool for scripting a repeatable setup, working over a remote session, or fixing a configuration on a machine where the GUI is inconvenient. This is the complete reference for the commands the official documentation describes.</p>



<h2 class="wp-block-heading">Getting a setupc prompt</h2>



<p class="wp-block-paragraph">setupc lives in the com0com installation folder, and the package installs a &#8220;Setup Command Prompt&#8221; shortcut that opens it there, ready to use. Run it <strong>as administrator</strong>: creating and changing driver ports is a privileged operation, and a non-elevated prompt will fail. At the interactive prompt you type commands after the <code>command&gt;</code> cursor. setupc also accepts a command directly as its arguments — <code>setupc install - -</code> from an ordinary elevated console does the same thing — which is exactly what makes batch-file scripting possible (last section).</p>



<p class="wp-block-paragraph">Forgotten a command&#8217;s shape? The built-in help is the authoritative syntax reference for your exact build — worth consulting even if you know the commands, because it lists every setting a <code>change</code> command accepts on this installation, including ones this reference does not dwell on:</p>



<pre class="wp-block-code"><code>command&gt; help</code></pre>



<h2 class="wp-block-heading">install — create a pair</h2>



<pre class="wp-block-code"><code>command&gt; install - -</code></pre>



<p class="wp-block-paragraph">This creates one virtual port pair with the next free default names. Each <code>-</code> placeholder means &#8220;assign the default name for this end&#8221;, so on a fresh system the result is CNCA0 and CNCB0; on a system that already has a pair, CNCA1 and CNCB1. The command reports the names it created. A newly installed system already has the first pair from setup, so you will use <code>install</code> mainly for second and subsequent pairs — or to recreate a pair you removed. There is no practical count limit: the official FAQ gives an internal ceiling of 1,000,000 pairs.</p>



<h2 class="wp-block-heading">change — rename ports and set options</h2>



<p class="wp-block-paragraph"><code>change</code> modifies one existing port. Its form is <code>change &lt;port&gt; &lt;setting&gt;=&lt;value&gt;</code>, and it backs every per-port option you can set in SetupG.</p>



<p class="wp-block-paragraph"><strong>Rename a port</strong> to a standard COM name (which also places it in the Windows Ports class, so applications can discover it):</p>



<pre class="wp-block-code"><code>command&gt; change CNCA0 PortName=COM8</code></pre>



<p class="wp-block-paragraph"><strong>Enable baud rate emulation</strong> on a port, so data sent from it is paced at the baud rate the application selected instead of arriving instantly (off by default):</p>



<pre class="wp-block-code"><code>command&gt; change CNCA0 EmuBR=yes</code></pre>



<p class="wp-block-paragraph"><strong>Enable receive buffer overrun emulation</strong> on the receiving port, so it can drop data like real hardware when the reader is too slow — the ReadMe&#8217;s FAQ also recommends this setting for the receiving end when data appears to hang in a pair:</p>



<pre class="wp-block-code"><code>command&gt; change CNCB0 EmuOverrun=yes</code></pre>



<p class="wp-block-paragraph"><strong>Noise emulation</strong> randomly corrupts data with a chosen probability, for protocol robustness testing:</p>



<pre class="wp-block-code"><code>command&gt; change CNCA0 EmuNoise=&lt;probability&gt;</code></pre>



<p class="wp-block-paragraph">To undo an emulation option, set it back to <code>no</code> (for example <code>change CNCA0 EmuBR=no</code>). Close any application that has the port open before changing it; an open port keeps the configuration it started with. The reasoning behind each option is explained in the <a href="/setupg-guide/">SetupG guide</a> and the <a href="/rename-com0com-port/">renaming guide</a>.</p>



<h2 class="wp-block-heading">list — show the current configuration</h2>



<pre class="wp-block-code"><code>command&gt; list</code></pre>



<p class="wp-block-paragraph"><code>list</code> prints every pair and port the driver currently has, with their names and settings. Run it after every <code>install</code> or <code>change</code> to verify the result is what you intended — it is the console equivalent of eyeballing the pair list in SetupG, and the fastest way to answer &#8220;what is this machine actually configured with?&#8221; on a system someone else set up.</p>



<h2 class="wp-block-heading">remove — delete a pair</h2>



<pre class="wp-block-code"><code>command&gt; remove CNCA0 CNCB0</code></pre>



<p class="wp-block-paragraph"><code>remove</code> deletes a pair, naming both of its ports. Both ends go together — you cannot remove half a pair, because a pair is a single cross-connected object. Make sure no application has either port open first; an open handle can block the removal. After removing, <code>list</code> confirms the pair is gone, and the port names (including any COM numbers you had assigned) are free to reuse.</p>



<h2 class="wp-block-heading">update — refresh the ports after a driver change</h2>



<pre class="wp-block-code"><code>command&gt; update</code></pre>



<p class="wp-block-paragraph"><code>update</code> re-applies the current configuration to the driver — the command to reach for after reinstalling or updating the driver itself, when existing pairs need to be re-registered against it. In day-to-day use you will rarely need it; <code>install</code> and <code>change</code> already commit their work. If pairs are missing entirely and <code>update</code> brings nothing back, suspect the driver rather than the configuration: check Device Manager for a Code 52 signature rejection (see the <a href="/install-com0com-windows-11/">installation guide</a>).</p>



<h2 class="wp-block-heading">When a command does not do what you expected</h2>



<ul class="wp-block-list">
<li><strong>Access is denied / the command fails instantly.</strong> The prompt is not elevated. Close it and reopen the Setup Command Prompt as administrator — driver configuration cannot be changed from a standard-user console, and setupc will not always spell that out.</li>



<li><strong>&#8220;Port not found&#8221; style errors on <code>change</code> or <code>remove</code>.</strong> The name you typed is not the name the driver knows. Run <code>list</code> and copy the exact name — a port you renamed to COM8 is changed by its current identity, and a pair&#8217;s second end is CNCB<em>n</em>, not a second CNCA.</li>



<li><strong>A <code>change</code> seems to be ignored.</strong> An application has the port open and is holding the old configuration. Close every program connected to either end of the pair, then repeat the change and verify with <code>list</code>.</li>



<li><strong><code>install</code> created different names than your script assumed.</strong> Default numbering continues from the pairs already present. On a machine with one existing pair, your new pair is CNCA1/CNCB1, not CNCA0/CNCB0 — read the names from the <code>install</code> output instead of assuming them.</li>



<li><strong>Nothing exists to change at all.</strong> If <code>list</code> shows no pairs on a fresh install, the driver itself likely failed to load. That is not a setupc problem — check Device Manager for Code 52 and work through the <a href="/install-com0com-windows-11/">installation guide</a>.</li>
</ul>


<h2 class="wp-block-heading">Scripting a pair in a batch file</h2>



<p class="wp-block-paragraph">Because setupc accepts commands as arguments, a complete, repeatable pair setup is a four-line batch file. Run it elevated, from (or pointing at) the com0com installation folder:</p>



<pre class="wp-block-code"><code>@echo off
setupc install - -
setupc change CNCA0 PortName=COM10
setupc change CNCB0 PortName=COM11
setupc list</code></pre>



<p class="wp-block-paragraph">That creates a fresh pair and immediately renames it to COM10/COM11, then prints the resulting configuration so your log shows exactly what was built on that machine. Two scripting cautions: the default names in the <code>change</code> lines assume the pair you just created received the CNCA0/CNCB0 names — on a machine that already has pairs, the new pair gets the next numbers, so read them from the <code>install</code> output or an initial <code>list</code> and adjust. And keep the script&#8217;s port numbers consistent with your machines&#8217; physical hardware, so a scripted COM10 never collides with a real adapter that happens to be plugged in that day.</p>



<p class="wp-block-paragraph">From here, put the pair to work: the <a href="/create-virtual-com-port-pair/">first-pair walkthrough</a> ends with a loopback test you can run against your scripted ports to prove the whole chain. Remaining questions — what the emulation options are for, why a port does not appear in an application — are answered in the <a href="/faq/">FAQ</a> and across the <a href="/guides/">Guides archive</a>.</p>

]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/setupc-commands/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>SetupG Guide: com0com&#8217;s Graphical Setup Utility, Explained</title>
		<link>https://com0com.com/setupg-guide/</link>
					<comments>https://com0com.com/setupg-guide/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 04:00:00 +0000</pubDate>
				<category><![CDATA[Guides]]></category>
		<guid isPermaLink="false">https://com0com.com/?p=548</guid>

					<description><![CDATA[SetupG is the friendly face of com0com: the official graphical setup utility that installs alongside the driver. Everything you can do by clicking in SetupG, you can also do with the setupc.exe command prompt — SetupG is literally a GUI wrapper around the same settings — but for creating pairs, renaming ports and switching emulation...]]></description>
										<content:encoded><![CDATA[
<ul class="wp-block-list">
<li><strong>Close applications first.</strong> A port held open by a terminal or your software keeps running with the settings it opened under. Close it, apply the change, reopen.</li>



<li><strong>Recreate stubborn pairs.</strong> If a rename or option change refuses to stick on an existing pair, remove the pair and add it again with the final settings. Recreating a pair costs seconds and clears half-configured states.</li>



<li><strong>A reboot is rarely required</strong> for configuration changes — but driver-level problems are a different matter. If <em>no</em> pairs appear at all, or the pair list is empty after installation, the driver itself probably never loaded (check Device Manager for Code 52) and no amount of SetupG clicking will help; go back to the <a href="/install-com0com-windows-11/">installation guide</a>.</li>
</ul>


<h2 class="wp-block-heading">When SetupG itself is the problem</h2>



<ul class="wp-block-list">
<li><strong>SetupG will not start, but the driver works.</strong> Check the .NET Framework requirement: SetupG needs .NET Framework 2.0 available. On such a system, configure with <a href="/setupc-commands/">setupc</a> instead — it edits exactly the same settings.</li>



<li><strong>Changes will not save.</strong> You are almost certainly running it without administrator rights. Close it and relaunch elevated; driver configuration is a privileged operation.</li>



<li><strong>The pair list is completely empty.</strong> That is not a SetupG fault: it means the driver has no ports to show, which on a fresh install points back to the driver not loading (Device Manager, Code 52). SetupG configures a running driver; it cannot substitute for one.</li>



<li><strong>One pair behaves differently from its settings.</strong> An application that opened the port earlier is still running it under the old configuration. Close the application completely — not just its document window — then check the pair again.</li>
</ul>


<h2 class="wp-block-heading">SetupG or setupc: which should you use?</h2>



<p class="wp-block-paragraph">For one-off configuration on your own machine, SetupG. The command prompt, <a href="/setupc-commands/">setupc.exe</a>, earns its keep when you need to repeat the same setup on several machines, script a test bench that builds pairs automatically, or work on a system where SetupG&#8217;s .NET requirement is a problem. Both tools edit the same configuration, so feel free to mix them — create the pair in SetupG, rename it from a script, and verify with whichever is open. Any remaining questions about what the options mean are collected in the <a href="/faq/">FAQ</a>, and all of this site&#8217;s walkthroughs live in the <a href="/guides/">Guides archive</a>.</p>

<!-- /wp:list -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Port name (PortName).</strong> The port&#8217;s name. Leave it as CNCA<em>n</em>/CNCB<em>n</em>, or assign a standard name with the <code>PortName=COM#</code> form — for example COM8 — which also places the port in the Windows Ports class so ordinary applications can discover it. This is the setting behind the whole <a href="/rename-com0com-port/">renaming guide</a>.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Baud rate emulation (EmuBR).</strong> Off by default. With it off, data crosses the pair as fast as memory allows, ignoring the baud rate the application selected. Switch it <em>on</em> for a port when the receiving side must experience realistic serial timing — for example when testing software that misbehaves if a whole message arrives instantly instead of dribbling in at 9600 baud. It applies to data sent <em>from</em> that port.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Buffer overrun emulation (EmuOverrun).</strong> Off by default. A real serial port has a small receive buffer; if the receiving program does not read fast enough, incoming bytes are lost in an overrun. A virtual pair normally never loses data that way. Enabling overrun emulation on a port makes it behave like hardware — the receive buffer can overrun and drop data — which is what you want when testing how your software copes with that failure. The ReadMe&#8217;s FAQ also suggests switching it on for the receiving port in a specific troubleshooting situation, when data seems to hang or stale characters linger in a pair.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Noise emulation (EmuNoise).</strong> Real serial lines occasionally corrupt a byte. Noise emulation reproduces that: with it enabled, the driver randomly corrupts data passing through the port with a probability you set. It exists purely for robustness testing — if your protocol claims to detect bad checksums and recover, this is how you prove it without faulty hardware. Leave it off for any real work; corrupted data in a production link is a bug, not a feature.</li>
<!-- /wp:list-item --></ul>

<!-- wp:paragraph -->
<p>Notice what is <em>not</em> in this list: performance tuning. There are no documented settings to make the pair &#8220;faster&#8221; or lower-latency, because a virtual pair is already a memory-to-memory copy. If a guide elsewhere promises speed options in SetupG, it is inventing them.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Applying changes — and when more is needed</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Most SetupG changes take effect when you apply them, for pairs and ports that are not currently open. Three practical rules cover nearly every &#8220;my change did nothing&#8221; report:</p>
<!-- /wp:paragraph -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Close applications first.</strong> A port held open by a terminal or your software keeps running with the settings it opened under. Close it, apply the change, reopen.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Recreate stubborn pairs.</strong> If a rename or option change refuses to stick on an existing pair, remove the pair and add it again with the final settings. Recreating a pair costs seconds and clears half-configured states.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>A reboot is rarely required</strong> for configuration changes — but driver-level problems are a different matter. If <em>no</em> pairs appear at all, or the pair list is empty after installation, the driver itself probably never loaded (check Device Manager for Code 52) and no amount of SetupG clicking will help; go back to the <a href="/install-com0com-windows-11/">installation guide</a>.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">When SetupG itself is the problem</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>SetupG will not start, but the driver works.</strong> Check the .NET Framework requirement: SetupG needs .NET Framework 2.0 available. On such a system, configure with <a href="/setupc-commands/">setupc</a> instead — it edits exactly the same settings.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Changes will not save.</strong> You are almost certainly running it without administrator rights. Close it and relaunch elevated; driver configuration is a privileged operation.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>The pair list is completely empty.</strong> That is not a SetupG fault: it means the driver has no ports to show, which on a fresh install points back to the driver not loading (Device Manager, Code 52). SetupG configures a running driver; it cannot substitute for one.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>One pair behaves differently from its settings.</strong> An application that opened the port earlier is still running it under the old configuration. Close the application completely — not just its document window — then check the pair again.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">SetupG or setupc: which should you use?</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>For one-off configuration on your own machine, SetupG. The command prompt, <a href="/setupc-commands/">setupc.exe</a>, earns its keep when you need to repeat the same setup on several machines, script a test bench that builds pairs automatically, or work on a system where SetupG&#8217;s .NET requirement is a problem. Both tools edit the same configuration, so feel free to mix them — create the pair in SetupG, rename it from a script, and verify with whichever is open. Any remaining questions about what the options mean are collected in the <a href="/faq/">FAQ</a>, and all of this site&#8217;s walkthroughs live in the <a href="/guides/">Guides archive</a>.</p>
<!-- /wp:paragraph -->
<!-- /wp:post-content --><!-- /wp:list --><!-- wp:post-content --><!-- wp:paragraph -->
<p>SetupG is the friendly face of com0com: the official graphical setup utility that installs alongside the driver. Everything you can do by clicking in SetupG, you can also do with the setupc.exe command prompt — SetupG is literally a GUI wrapper around the same settings — but for creating pairs, renaming ports and switching emulation options, the window is faster and much harder to get wrong. This guide tours the whole tool: what each part shows, what each per-port option honestly does, and when a change needs more than a click.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">What SetupG is (and what it is not)</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>SetupG (<code>setupg.exe</code>) has been part of the com0com package since version 2.0.0.0. It is not a third-party add-on and it is not a monitoring tool: it does not show traffic flowing through your ports. Its single job is <em>configuration</em> — which pairs exist, what each port is called, and which emulation behaviours are switched on. One practical requirement from the ReadMe: SetupG needs the <strong>.NET Framework 2.0</strong>, which modern Windows versions satisfy through their built-in compatibility, but on a stripped-down system it explains a SetupG that refuses to start while setupc works fine.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>You will find SetupG in the com0com folder in the Start menu. Run it with administrator rights — changing driver configuration without elevation will fail or silently not stick.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">The main window: your pair list</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The main window lists every virtual port the driver currently has, organised as pairs. On a fresh installation you will see exactly one pair: <strong>CNCA0 ↔ CNCB0</strong>, created by the installer. Selecting a pair shows its two ports; selecting a single port shows that port&#8217;s individual settings, which is where all the interesting options live. Treat this list as the source of truth for your configuration — if a pair is not listed here, applications cannot use it, whatever you may have set up in the past.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Adding and removing pairs</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p><strong>Add Pair</strong> creates a new pair with the next free default names (CNCA1/CNCB1, then CNCA2/CNCB2, and so on). There is no practical limit to how many you can add — the official FAQ puts the driver&#8217;s internal ceiling at 1,000,000 pairs. Before applying, rename the new ports if your applications need standard COM names; the rename field is right there in the port settings, and doing it at creation time saves a second pass.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>Removing a pair deletes both of its ports. Close any application connected to either end first: an application holding a port open can block the removal or be left talking to a port that no longer exists. If a removal seems to be ignored, an open handle is the first thing to check. The step-by-step creation flow, including the loopback test to run afterwards, is in <a href="/create-virtual-com-port-pair/">Create Your First Virtual COM Port Pair</a>.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Per-port options, honestly explained</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Each port in a pair carries its own settings. These are the ones the official ReadMe documents:</p>
<!-- /wp:paragraph -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Port name (PortName).</strong> The port&#8217;s name. Leave it as CNCA<em>n</em>/CNCB<em>n</em>, or assign a standard name with the <code>PortName=COM#</code> form — for example COM8 — which also places the port in the Windows Ports class so ordinary applications can discover it. This is the setting behind the whole <a href="/rename-com0com-port/">renaming guide</a>.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Baud rate emulation (EmuBR).</strong> Off by default. With it off, data crosses the pair as fast as memory allows, ignoring the baud rate the application selected. Switch it <em>on</em> for a port when the receiving side must experience realistic serial timing — for example when testing software that misbehaves if a whole message arrives instantly instead of dribbling in at 9600 baud. It applies to data sent <em>from</em> that port.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Buffer overrun emulation (EmuOverrun).</strong> Off by default. A real serial port has a small receive buffer; if the receiving program does not read fast enough, incoming bytes are lost in an overrun. A virtual pair normally never loses data that way. Enabling overrun emulation on a port makes it behave like hardware — the receive buffer can overrun and drop data — which is what you want when testing how your software copes with that failure. The ReadMe&#8217;s FAQ also suggests switching it on for the receiving port in a specific troubleshooting situation, when data seems to hang or stale characters linger in a pair.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Noise emulation (EmuNoise).</strong> Real serial lines occasionally corrupt a byte. Noise emulation reproduces that: with it enabled, the driver randomly corrupts data passing through the port with a probability you set. It exists purely for robustness testing — if your protocol claims to detect bad checksums and recover, this is how you prove it without faulty hardware. Leave it off for any real work; corrupted data in a production link is a bug, not a feature.</li>
<!-- /wp:list-item --></ul>

<!-- wp:paragraph -->
<p>Notice what is <em>not</em> in this list: performance tuning. There are no documented settings to make the pair &#8220;faster&#8221; or lower-latency, because a virtual pair is already a memory-to-memory copy. If a guide elsewhere promises speed options in SetupG, it is inventing them.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Applying changes — and when more is needed</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Most SetupG changes take effect when you apply them, for pairs and ports that are not currently open. Three practical rules cover nearly every &#8220;my change did nothing&#8221; report:</p>
<!-- /wp:paragraph -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Close applications first.</strong> A port held open by a terminal or your software keeps running with the settings it opened under. Close it, apply the change, reopen.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Recreate stubborn pairs.</strong> If a rename or option change refuses to stick on an existing pair, remove the pair and add it again with the final settings. Recreating a pair costs seconds and clears half-configured states.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>A reboot is rarely required</strong> for configuration changes — but driver-level problems are a different matter. If <em>no</em> pairs appear at all, or the pair list is empty after installation, the driver itself probably never loaded (check Device Manager for Code 52) and no amount of SetupG clicking will help; go back to the <a href="/install-com0com-windows-11/">installation guide</a>.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">When SetupG itself is the problem</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>SetupG will not start, but the driver works.</strong> Check the .NET Framework requirement: SetupG needs .NET Framework 2.0 available. On such a system, configure with <a href="/setupc-commands/">setupc</a> instead — it edits exactly the same settings.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Changes will not save.</strong> You are almost certainly running it without administrator rights. Close it and relaunch elevated; driver configuration is a privileged operation.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>The pair list is completely empty.</strong> That is not a SetupG fault: it means the driver has no ports to show, which on a fresh install points back to the driver not loading (Device Manager, Code 52). SetupG configures a running driver; it cannot substitute for one.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>One pair behaves differently from its settings.</strong> An application that opened the port earlier is still running it under the old configuration. Close the application completely — not just its document window — then check the pair again.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">SetupG or setupc: which should you use?</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>For one-off configuration on your own machine, SetupG. The command prompt, <a href="/setupc-commands/">setupc.exe</a>, earns its keep when you need to repeat the same setup on several machines, script a test bench that builds pairs automatically, or work on a system where SetupG&#8217;s .NET requirement is a problem. Both tools edit the same configuration, so feel free to mix them — create the pair in SetupG, rename it from a script, and verify with whichever is open. Any remaining questions about what the options mean are collected in the <a href="/faq/">FAQ</a>, and all of this site&#8217;s walkthroughs live in the <a href="/guides/">Guides archive</a>.</p>
<!-- /wp:paragraph -->
<!-- /wp:post-content -->]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/setupg-guide/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Rename com0com Ports: Turn CNCA0 and CNCB0 into Real COM Ports</title>
		<link>https://com0com.com/rename-com0com-port/</link>
					<comments>https://com0com.com/rename-com0com-port/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 03:00:00 +0000</pubDate>
				<category><![CDATA[Guides]]></category>
		<guid isPermaLink="false">https://com0com.com/?p=547</guid>

					<description><![CDATA[You installed com0com, the driver loaded, the pair exists — and your application still shows an empty port list, or only offers COM1 and COM2. This is the single most common com0com problem, and it is almost never a driver fault. Your ports are named CNCA0 and CNCB0, and a large share of serial software...]]></description>
										<content:encoded><![CDATA[
<ol class="wp-block-list">
<li>In <strong>Device Manager</strong>, expand <em>Ports (COM &amp; LPT)</em>. Your renamed ports should now be listed there with their COM names — this is the clearest sign the Ports-class assignment worked.</li>



<li>In <strong>your application</strong>, reopen the port selection list. The COM names should now appear alongside any physical ports. If the application was already running, restart it — many programs only scan ports once, at startup.</li>



<li>Run the <a href="/create-virtual-com-port-pair/">two-window loopback test</a> against the new names: connect one terminal window to each COM name and confirm characters flow in both directions.</li>
</ol>


<h2 class="wp-block-heading">What if the COM number you want is &#8220;already in use&#8221;?</h2>



<p class="wp-block-paragraph">Sometimes Windows insists a COM number is taken even though no visible device uses it. The usual cause is a <strong>ghost reservation</strong>: Windows remembers COM numbers assigned to devices that were uninstalled or unplugged, and Device Manager hides those phantom entries unless you ask it to show hidden devices. This is a general Windows housekeeping issue rather than a com0com fault. For now, the pragmatic fixes are to pick the next free number — virtual pairs genuinely do not care which numbers they use — or to clean up the phantom assignments. The <a href="/faq/">FAQ</a> collects the short version of the ghost-port story, and a full cleanup walkthrough is on this site&#8217;s troubleshooting roadmap.</p>



<h2 class="wp-block-heading">Common renaming mistakes</h2>



<ul class="wp-block-list">
<li><strong>Giving both ends the same name.</strong> The two ends of a pair are separate ports and must have different names. If an application connects to &#8220;COM8&#8221; it reaches exactly one end; the other program must open the other end&#8217;s name. Same-name confusion usually shows up as a port that opens fine but never receives anything.</li>



<li><strong>Renaming only in your head.</strong> Changing a label in your notes — or in an application&#8217;s settings — does nothing. The rename has to happen in SetupG or setupc, against the port itself. If <code>list</code> still shows CNCA0, the rename did not happen, whatever your application is configured to look for.</li>



<li><strong>Expecting running applications to notice.</strong> Port lists are almost always built once, when a program starts. A program opened before the rename will not show the new name until you restart it — this alone accounts for most &#8220;the rename didn&#8217;t work&#8221; reports.</li>



<li><strong>Reusing a physical port&#8217;s number &#8220;because it&#8217;s unplugged right now&#8221;.</strong> The day the USB adapter goes back in, two devices claim one number and whichever registered second loses. Virtual ports are free — spend a number that is permanently yours.</li>
</ul>


<h2 class="wp-block-heading">A naming habit that pays off later</h2>



<p class="wp-block-paragraph">If you run more than one pair — a simulator pair, a logging pair, a spare — name them in a pattern and write it down: for example COM10/COM11 for the device simulator, COM12/COM13 for the application under test. Months later, when a script or a colleague asks &#8220;which port does the simulator live on?&#8221;, the pattern answers it. It is also worth keeping the CNCA/CNCB names of each end in the same note: SetupG and setupc always know the original names, and troubleshooting a pair is easier when you can refer to an end unambiguously regardless of its current COM number. None of this is required — but the five minutes it takes is repaid the first time a test bench grows beyond a single pair.</p>



<p class="wp-block-paragraph">One more subtle case: if you renamed a port while an application had the old name open, that application keeps its handle on the old configuration until it is closed. Always close serial applications before renaming, and reopen them afterwards. If a port still refuses to appear after a verified rename and an application restart, work through the installation checks in the <a href="/install-com0com-windows-11/">Windows 11 install guide</a> — in particular, confirm the driver itself loaded without Code 52, because a driver that never started cannot publish any ports, renamed or not. Everything else about names, pairs and defaults is gathered in the <a href="/guides/">Guides archive</a>.</p>

<!-- /wp:list -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Avoid COM1 and COM2.</strong> Legacy software frequently assumes these are physical motherboard ports, and some machines genuinely have them reserved.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Check what is already taken.</strong> Open Device Manager, expand <em>Ports (COM &amp; LPT)</em>, and note every number in use by physical serial ports, USB-to-serial adapters, and Bluetooth serial links. Pick numbers outside that set.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Stay in a tidy range.</strong> COM5–COM20 is a practical band for virtual pairs: high enough to avoid legacy assumptions, low enough that even old software that only scans single- or double-digit ports will find them. Note that a few very old programs cannot open ports above COM9 at all — if you are feeding a decades-old application, keep its end of the pair at COM9 or below.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Rename both ends.</strong> Renaming only one end leaves the other invisible to the same class of application. Give every end you plan to expose a COM name.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">Verify the rename worked</h2>
<!-- /wp:heading -->

<!-- wp:list {"ordered":true} -->
<ol class="wp-block-list"><!-- wp:list-item -->
<li>In <strong>Device Manager</strong>, expand <em>Ports (COM &amp; LPT)</em>. Your renamed ports should now be listed there with their COM names — this is the clearest sign the Ports-class assignment worked.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>In <strong>your application</strong>, reopen the port selection list. The COM names should now appear alongside any physical ports. If the application was already running, restart it — many programs only scan ports once, at startup.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Run the <a href="/create-virtual-com-port-pair/">two-window loopback test</a> against the new names: connect one terminal window to each COM name and confirm characters flow in both directions.</li>
<!-- /wp:list-item --></ol>

<!-- wp:heading -->
<h2 class="wp-block-heading">What if the COM number you want is &#8220;already in use&#8221;?</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Sometimes Windows insists a COM number is taken even though no visible device uses it. The usual cause is a <strong>ghost reservation</strong>: Windows remembers COM numbers assigned to devices that were uninstalled or unplugged, and Device Manager hides those phantom entries unless you ask it to show hidden devices. This is a general Windows housekeeping issue rather than a com0com fault. For now, the pragmatic fixes are to pick the next free number — virtual pairs genuinely do not care which numbers they use — or to clean up the phantom assignments. The <a href="/faq/">FAQ</a> collects the short version of the ghost-port story, and a full cleanup walkthrough is on this site&#8217;s troubleshooting roadmap.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Common renaming mistakes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Giving both ends the same name.</strong> The two ends of a pair are separate ports and must have different names. If an application connects to &#8220;COM8&#8221; it reaches exactly one end; the other program must open the other end&#8217;s name. Same-name confusion usually shows up as a port that opens fine but never receives anything.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Renaming only in your head.</strong> Changing a label in your notes — or in an application&#8217;s settings — does nothing. The rename has to happen in SetupG or setupc, against the port itself. If <code>list</code> still shows CNCA0, the rename did not happen, whatever your application is configured to look for.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Expecting running applications to notice.</strong> Port lists are almost always built once, when a program starts. A program opened before the rename will not show the new name until you restart it — this alone accounts for most &#8220;the rename didn&#8217;t work&#8221; reports.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Reusing a physical port&#8217;s number &#8220;because it&#8217;s unplugged right now&#8221;.</strong> The day the USB adapter goes back in, two devices claim one number and whichever registered second loses. Virtual ports are free — spend a number that is permanently yours.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">A naming habit that pays off later</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>If you run more than one pair — a simulator pair, a logging pair, a spare — name them in a pattern and write it down: for example COM10/COM11 for the device simulator, COM12/COM13 for the application under test. Months later, when a script or a colleague asks &#8220;which port does the simulator live on?&#8221;, the pattern answers it. It is also worth keeping the CNCA/CNCB names of each end in the same note: SetupG and setupc always know the original names, and troubleshooting a pair is easier when you can refer to an end unambiguously regardless of its current COM number. None of this is required — but the five minutes it takes is repaid the first time a test bench grows beyond a single pair.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>One more subtle case: if you renamed a port while an application had the old name open, that application keeps its handle on the old configuration until it is closed. Always close serial applications before renaming, and reopen them afterwards. If a port still refuses to appear after a verified rename and an application restart, work through the installation checks in the <a href="/install-com0com-windows-11/">Windows 11 install guide</a> — in particular, confirm the driver itself loaded without Code 52, because a driver that never started cannot publish any ports, renamed or not. Everything else about names, pairs and defaults is gathered in the <a href="/guides/">Guides archive</a>.</p>
<!-- /wp:paragraph -->
<!-- /wp:post-content --><!-- /wp:list -->

<!-- wp:list {"ordered":true} -->
<ol class="wp-block-list"><!-- wp:list-item -->
<li>Open <strong>SetupG</strong> (administrator rights) and select the port you want to rename in the pair list — for example CNCA0.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>In that port&#8217;s settings, set its port name to the COM name you want, using the <code>PortName=COM#</code> form: enter <strong>COM8</strong> as the new name (SetupG applies it as the port&#8217;s PortName).</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Repeat for the other end of the pair, choosing a different number — if CNCA0 becomes COM8, make CNCB0 COM9.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Apply the changes, and close any application that had the old names open.</li>
<!-- /wp:list-item --></ol>

<!-- wp:paragraph -->
<p>The <a href="/setupg-guide/">SetupG guide</a> tours every option in that window, including the emulation settings that live next to the port name.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Method 2: Rename with setupc</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The same change from the Setup Command Prompt is one line per port:</p>
<!-- /wp:paragraph -->

<!-- wp:code -->
<pre class="wp-block-code"><code>command&gt; change CNCA0 PortName=COM8
command&gt; change CNCB0 PortName=COM9</code></pre>
<!-- /wp:code -->

<!-- wp:paragraph -->
<p>Run <code>list</code> afterwards to confirm the new names took effect. This is also the fastest way to rename several pairs when you are scripting a test bench — the full command reference is in the <a href="/setupc-commands/">setupc.exe command guide</a>.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Choosing a COM number that will not cause trouble</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Avoid COM1 and COM2.</strong> Legacy software frequently assumes these are physical motherboard ports, and some machines genuinely have them reserved.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Check what is already taken.</strong> Open Device Manager, expand <em>Ports (COM &amp; LPT)</em>, and note every number in use by physical serial ports, USB-to-serial adapters, and Bluetooth serial links. Pick numbers outside that set.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Stay in a tidy range.</strong> COM5–COM20 is a practical band for virtual pairs: high enough to avoid legacy assumptions, low enough that even old software that only scans single- or double-digit ports will find them. Note that a few very old programs cannot open ports above COM9 at all — if you are feeding a decades-old application, keep its end of the pair at COM9 or below.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Rename both ends.</strong> Renaming only one end leaves the other invisible to the same class of application. Give every end you plan to expose a COM name.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">Verify the rename worked</h2>
<!-- /wp:heading -->

<!-- wp:list {"ordered":true} -->
<ol class="wp-block-list"><!-- wp:list-item -->
<li>In <strong>Device Manager</strong>, expand <em>Ports (COM &amp; LPT)</em>. Your renamed ports should now be listed there with their COM names — this is the clearest sign the Ports-class assignment worked.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>In <strong>your application</strong>, reopen the port selection list. The COM names should now appear alongside any physical ports. If the application was already running, restart it — many programs only scan ports once, at startup.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Run the <a href="/create-virtual-com-port-pair/">two-window loopback test</a> against the new names: connect one terminal window to each COM name and confirm characters flow in both directions.</li>
<!-- /wp:list-item --></ol>

<!-- wp:heading -->
<h2 class="wp-block-heading">What if the COM number you want is &#8220;already in use&#8221;?</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Sometimes Windows insists a COM number is taken even though no visible device uses it. The usual cause is a <strong>ghost reservation</strong>: Windows remembers COM numbers assigned to devices that were uninstalled or unplugged, and Device Manager hides those phantom entries unless you ask it to show hidden devices. This is a general Windows housekeeping issue rather than a com0com fault. For now, the pragmatic fixes are to pick the next free number — virtual pairs genuinely do not care which numbers they use — or to clean up the phantom assignments. The <a href="/faq/">FAQ</a> collects the short version of the ghost-port story, and a full cleanup walkthrough is on this site&#8217;s troubleshooting roadmap.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Common renaming mistakes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Giving both ends the same name.</strong> The two ends of a pair are separate ports and must have different names. If an application connects to &#8220;COM8&#8221; it reaches exactly one end; the other program must open the other end&#8217;s name. Same-name confusion usually shows up as a port that opens fine but never receives anything.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Renaming only in your head.</strong> Changing a label in your notes — or in an application&#8217;s settings — does nothing. The rename has to happen in SetupG or setupc, against the port itself. If <code>list</code> still shows CNCA0, the rename did not happen, whatever your application is configured to look for.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Expecting running applications to notice.</strong> Port lists are almost always built once, when a program starts. A program opened before the rename will not show the new name until you restart it — this alone accounts for most &#8220;the rename didn&#8217;t work&#8221; reports.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Reusing a physical port&#8217;s number &#8220;because it&#8217;s unplugged right now&#8221;.</strong> The day the USB adapter goes back in, two devices claim one number and whichever registered second loses. Virtual ports are free — spend a number that is permanently yours.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">A naming habit that pays off later</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>If you run more than one pair — a simulator pair, a logging pair, a spare — name them in a pattern and write it down: for example COM10/COM11 for the device simulator, COM12/COM13 for the application under test. Months later, when a script or a colleague asks &#8220;which port does the simulator live on?&#8221;, the pattern answers it. It is also worth keeping the CNCA/CNCB names of each end in the same note: SetupG and setupc always know the original names, and troubleshooting a pair is easier when you can refer to an end unambiguously regardless of its current COM number. None of this is required — but the five minutes it takes is repaid the first time a test bench grows beyond a single pair.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>One more subtle case: if you renamed a port while an application had the old name open, that application keeps its handle on the old configuration until it is closed. Always close serial applications before renaming, and reopen them afterwards. If a port still refuses to appear after a verified rename and an application restart, work through the installation checks in the <a href="/install-com0com-windows-11/">Windows 11 install guide</a> — in particular, confirm the driver itself loaded without Code 52, because a driver that never started cannot publish any ports, renamed or not. Everything else about names, pairs and defaults is gathered in the <a href="/guides/">Guides archive</a>.</p>
<!-- /wp:paragraph -->
<!-- /wp:post-content --><!-- /wp:list --><!-- wp:post-content --><!-- wp:paragraph -->
<p>You installed com0com, the driver loaded, the pair exists — and your application still shows an empty port list, or only offers COM1 and COM2. This is the single most common com0com problem, and it is almost never a driver fault. Your ports are named CNCA0 and CNCB0, and a large share of serial software simply does not look for ports with names like that. This guide renames them to standard COM port names your applications can see.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Why applications cannot see CNCA0 and CNCB0</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>CNCA0 and CNCB0 are com0com&#8217;s internal port names. They are real ports — the driver created them, and tools that open ports by exact name can use them. But most Windows serial software builds its port list by scanning the standard Windows <strong>Ports class</strong>, the same place Device Manager lists &#8220;Ports (COM &amp; LPT)&#8221;. Ports appear there when they carry a standard <strong>COM</strong> name such as COM3 or COM10. By default, a fresh com0com pair does not — so to an application that scans the Ports class, the pair might as well not exist.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The good news: com0com was designed for this. Since version 3.0.0.0, assigning a port a name in the form <code>PortName=COM#</code> puts that port into the Ports class with a real COM name. Renaming is not a hack or a registry edit; it is a documented driver feature, and you can do it in the GUI or from the command line.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Method 1: Rename in SetupG</h2>
<!-- /wp:heading -->

<!-- wp:list {"ordered":true} -->
<ol class="wp-block-list"><!-- wp:list-item -->
<li>Open <strong>SetupG</strong> (administrator rights) and select the port you want to rename in the pair list — for example CNCA0.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>In that port&#8217;s settings, set its port name to the COM name you want, using the <code>PortName=COM#</code> form: enter <strong>COM8</strong> as the new name (SetupG applies it as the port&#8217;s PortName).</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Repeat for the other end of the pair, choosing a different number — if CNCA0 becomes COM8, make CNCB0 COM9.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Apply the changes, and close any application that had the old names open.</li>
<!-- /wp:list-item --></ol>

<!-- wp:paragraph -->
<p>The <a href="/setupg-guide/">SetupG guide</a> tours every option in that window, including the emulation settings that live next to the port name.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Method 2: Rename with setupc</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The same change from the Setup Command Prompt is one line per port:</p>
<!-- /wp:paragraph -->

<!-- wp:code -->
<pre class="wp-block-code"><code>command&gt; change CNCA0 PortName=COM8
command&gt; change CNCB0 PortName=COM9</code></pre>
<!-- /wp:code -->

<!-- wp:paragraph -->
<p>Run <code>list</code> afterwards to confirm the new names took effect. This is also the fastest way to rename several pairs when you are scripting a test bench — the full command reference is in the <a href="/setupc-commands/">setupc.exe command guide</a>.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Choosing a COM number that will not cause trouble</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Avoid COM1 and COM2.</strong> Legacy software frequently assumes these are physical motherboard ports, and some machines genuinely have them reserved.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Check what is already taken.</strong> Open Device Manager, expand <em>Ports (COM &amp; LPT)</em>, and note every number in use by physical serial ports, USB-to-serial adapters, and Bluetooth serial links. Pick numbers outside that set.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Stay in a tidy range.</strong> COM5–COM20 is a practical band for virtual pairs: high enough to avoid legacy assumptions, low enough that even old software that only scans single- or double-digit ports will find them. Note that a few very old programs cannot open ports above COM9 at all — if you are feeding a decades-old application, keep its end of the pair at COM9 or below.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Rename both ends.</strong> Renaming only one end leaves the other invisible to the same class of application. Give every end you plan to expose a COM name.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">Verify the rename worked</h2>
<!-- /wp:heading -->

<!-- wp:list {"ordered":true} -->
<ol class="wp-block-list"><!-- wp:list-item -->
<li>In <strong>Device Manager</strong>, expand <em>Ports (COM &amp; LPT)</em>. Your renamed ports should now be listed there with their COM names — this is the clearest sign the Ports-class assignment worked.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>In <strong>your application</strong>, reopen the port selection list. The COM names should now appear alongside any physical ports. If the application was already running, restart it — many programs only scan ports once, at startup.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Run the <a href="/create-virtual-com-port-pair/">two-window loopback test</a> against the new names: connect one terminal window to each COM name and confirm characters flow in both directions.</li>
<!-- /wp:list-item --></ol>

<!-- wp:heading -->
<h2 class="wp-block-heading">What if the COM number you want is &#8220;already in use&#8221;?</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Sometimes Windows insists a COM number is taken even though no visible device uses it. The usual cause is a <strong>ghost reservation</strong>: Windows remembers COM numbers assigned to devices that were uninstalled or unplugged, and Device Manager hides those phantom entries unless you ask it to show hidden devices. This is a general Windows housekeeping issue rather than a com0com fault. For now, the pragmatic fixes are to pick the next free number — virtual pairs genuinely do not care which numbers they use — or to clean up the phantom assignments. The <a href="/faq/">FAQ</a> collects the short version of the ghost-port story, and a full cleanup walkthrough is on this site&#8217;s troubleshooting roadmap.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Common renaming mistakes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li><strong>Giving both ends the same name.</strong> The two ends of a pair are separate ports and must have different names. If an application connects to &#8220;COM8&#8221; it reaches exactly one end; the other program must open the other end&#8217;s name. Same-name confusion usually shows up as a port that opens fine but never receives anything.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Renaming only in your head.</strong> Changing a label in your notes — or in an application&#8217;s settings — does nothing. The rename has to happen in SetupG or setupc, against the port itself. If <code>list</code> still shows CNCA0, the rename did not happen, whatever your application is configured to look for.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Expecting running applications to notice.</strong> Port lists are almost always built once, when a program starts. A program opened before the rename will not show the new name until you restart it — this alone accounts for most &#8220;the rename didn&#8217;t work&#8221; reports.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li><strong>Reusing a physical port&#8217;s number &#8220;because it&#8217;s unplugged right now&#8221;.</strong> The day the USB adapter goes back in, two devices claim one number and whichever registered second loses. Virtual ports are free — spend a number that is permanently yours.</li>
<!-- /wp:list-item --></ul>

<!-- wp:heading -->
<h2 class="wp-block-heading">A naming habit that pays off later</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>If you run more than one pair — a simulator pair, a logging pair, a spare — name them in a pattern and write it down: for example COM10/COM11 for the device simulator, COM12/COM13 for the application under test. Months later, when a script or a colleague asks &#8220;which port does the simulator live on?&#8221;, the pattern answers it. It is also worth keeping the CNCA/CNCB names of each end in the same note: SetupG and setupc always know the original names, and troubleshooting a pair is easier when you can refer to an end unambiguously regardless of its current COM number. None of this is required — but the five minutes it takes is repaid the first time a test bench grows beyond a single pair.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>One more subtle case: if you renamed a port while an application had the old name open, that application keeps its handle on the old configuration until it is closed. Always close serial applications before renaming, and reopen them afterwards. If a port still refuses to appear after a verified rename and an application restart, work through the installation checks in the <a href="/install-com0com-windows-11/">Windows 11 install guide</a> — in particular, confirm the driver itself loaded without Code 52, because a driver that never started cannot publish any ports, renamed or not. Everything else about names, pairs and defaults is gathered in the <a href="/guides/">Guides archive</a>.</p>
<!-- /wp:paragraph -->
<!-- /wp:post-content -->]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/rename-com0com-port/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Create Your First Virtual COM Port Pair with com0com</title>
		<link>https://com0com.com/create-virtual-com-port-pair/</link>
					<comments>https://com0com.com/create-virtual-com-port-pair/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 02:00:00 +0000</pubDate>
				<category><![CDATA[Guides]]></category>
		<guid isPermaLink="false">https://com0com.com/?p=546</guid>

					<description><![CDATA[A virtual COM port pair is the whole point of com0com: two virtual serial ports connected back-to-back in software, so anything one application sends into the first port comes out of the second, and vice versa — the software equivalent of a null-modem cable between two PCs. This walkthrough creates your first pair, renames it...]]></description>
										<content:encoded><![CDATA[
<ol class="wp-block-list">
<li>Open <strong>SetupG</strong> from the com0com folder in your Start menu, with administrator rights. You will see the existing pairs listed — at minimum the default CNCA0 ↔ CNCB0 pair from installation.</li>



<li>Click <strong>Add Pair</strong>. A new pair appears with the next free default names (for example CNCA1 and CNCB1).</li>



<li>Before you finish, consider renaming the new ports right away (next section). Default names work, but many applications cannot see them.</li>



<li>Apply the changes. Close any application that currently has one of the affected ports open first — a port in use cannot be reconfigured cleanly.</li>
</ol>


<h2 class="wp-block-heading">Method 2: Create a pair with setupc</h2>



<p class="wp-block-paragraph">Open the Setup Command Prompt (setupc.exe) from the com0com installation folder, as administrator. The command to add a pair with default names is:</p>



<pre class="wp-block-code"><code>command&gt; install - -</code></pre>



<p class="wp-block-paragraph">Each <code>-</code> tells setupc to assign the next default name for that end of the pair, which is why the result is a CNCA<em>n</em>/CNCB<em>n</em> pair. Run <code>list</code> afterwards to see every pair and port the driver currently has, and to confirm the new pair was added with the names you expected.</p>



<h2 class="wp-block-heading">Rename the pair while you are at it</h2>



<p class="wp-block-paragraph">Here is the step beginners skip and then lose an hour to: a large share of serial applications only enumerate ports with standard <strong>COM</strong> names. They will never offer CNCA0 in their port dropdown, no matter how correctly the driver is installed. The fix takes ten seconds. In SetupG, select the port and change its name using the <code>PortName=COM#</code> form — for example, turn CNCA0 into COM10 and CNCB0 into COM11. Assigning a name in that form also places the port in the Windows <strong>Ports class</strong>, so it appears in Device Manager alongside physical COM ports and becomes visible to applications that scan that class.</p>



<p class="wp-block-paragraph">The same change from setupc looks like this:</p>



<pre class="wp-block-code"><code>command&gt; change CNCA0 PortName=COM10
command&gt; change CNCB0 PortName=COM11</code></pre>



<p class="wp-block-paragraph">Pick numbers that are not already in use by physical hardware, Bluetooth serial links, or USB adapters, and avoid COM1 and COM2, which legacy software often assumes are motherboard ports. The full renaming guide — including what to do when the number you want seems taken — is <a href="/rename-com0com-port/">here</a>.</p>



<h2 class="wp-block-heading">Prove it works: the two-window loopback test</h2>



<p class="wp-block-paragraph">Before connecting any real software, verify the pair with the simplest test there is. You need any terminal program — PuTTY, Tera Term, or the terminal built into your development tools all work.</p>



<ol class="wp-block-list">
<li>Open the terminal and connect it to the <strong>first</strong> end of the pair (say COM10), using any settings — 9600 baud, 8 data bits, no parity, 1 stop bit is a fine starting point.</li>



<li>Open a <strong>second</strong> terminal window and connect it to the <strong>other</strong> end (COM11), with the same settings.</li>



<li>Type in the first window. Every character should appear in the second window — and nothing should appear in the window you typed in (unless your terminal has local echo switched on).</li>



<li>Type back from the second window to the first. If both directions work, your pair is fully functional.</li>
</ol>


<p class="wp-block-paragraph">If nothing arrives, check the basics before suspecting the driver: both windows must be connected to opposite ends of the <em>same</em> pair, no other program may hold either port open, and if you are using the CNCA/CNCB names, make sure your terminal can actually open them (the rename above solves this in most cases). More answers are in the <a href="/faq/">FAQ</a>.</p>



<h2 class="wp-block-heading">About baud rate, data bits and parity on a virtual pair</h2>



<p class="wp-block-paragraph">New users are often surprised that a virtual pair seems to ignore its speed setting. That is by design. With a physical cable, the baud rate is a real electrical signalling speed. With com0com, data moves through memory, so by default it is transferred as fast as the applications can handle, regardless of the baud rate the application selected — <strong>baud rate emulation (EmuBR) is off by default</strong>. The data bits, parity and stop-bit settings your application chooses are accepted, but there is no UART hardware enforcing them.</p>



<p class="wp-block-paragraph">Most of the time this instant, pass-through behaviour is exactly what you want — it is why virtual pairs are ideal for application-to-application links and for testing serial software. If you are developing software that must behave correctly at a real 9600 baud — for example, code that times out too aggressively when data arrives instantly — enable baud rate emulation for the sending port (in SetupG, or with <code>change CNCA0 EmuBR=yes</code> in setupc) and the driver will pace the data realistically. The <a href="/setupg-guide/">SetupG guide</a> covers EmuBR and its sibling options, overrun and noise emulation, in detail.</p>



<h2 class="wp-block-heading">One pair or many? Planning a small test bench</h2>



<p class="wp-block-paragraph">A single pair covers the classic case — one simulator talking to one application. Real test benches grow quickly, though: the application under test on one pair, a monitoring or logging setup watching a second scenario on another, a spare pair for the next experiment. Since pairs cost nothing and the driver supports an effectively unlimited number of them, create pairs per purpose rather than constantly reconfiguring one shared pair. Give each pair&#8217;s ends distinct COM names in a pattern (COM10/COM11 for the first setup, COM12/COM13 for the second) and jot down which pair serves which purpose. When a test misbehaves, that tiny bit of bookkeeping tells you instantly whether you are even looking at the right connection — a surprisingly common source of &#8220;com0com drops my data&#8221; reports that turn out to be two programs attached to different pairs.</p>



<p class="wp-block-paragraph">That is all a pair is: create it, give it real COM names, test it with two windows. From here the interesting part is what you connect to the ends — two of your own programs, a simulator and the software under test, or one end of a hub4com sharing setup. When you are ready to go further, the <a href="/guides/">Guides archive</a> collects every walkthrough on this site, and the <a href="/download/">download page</a> has the packages, including hub4com.</p>

<!-- /wp:list --><!-- wp:post-content --><!-- wp:paragraph -->
<p>A virtual COM port pair is the whole point of com0com: two virtual serial ports connected back-to-back in software, so anything one application sends into the first port comes out of the second, and vice versa — the software equivalent of a null-modem cable between two PCs. This walkthrough creates your first pair, renames it to something your applications can actually use, and proves it works with a two-window loopback test.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>This guide assumes com0com 3.0.0.0 is already installed and the driver loaded. If it is not, start with the <a href="/install-com0com-windows-11/">Windows 11 installation guide</a> (or the <a href="/com0com-windows-10/">Windows 10 guide</a>) and come back once Device Manager shows the driver without a Code 52 warning.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">What you get by default: CNCA0 and CNCB0</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The installer already creates one pair for you, named <strong>CNCA0</strong> and <strong>CNCB0</strong>. Those names are the driver&#8217;s internal naming scheme: CNCA/CNCB plus a number for each additional pair (CNCA1/CNCB1, and so on). The two ends are permanently cross-connected — CNCA0 talks only to CNCB0, never to a physical port or to another pair. And you are not limited to one pair: the official FAQ gives an internal limit of 1,000,000 pairs, which in practice means the number of pairs is unlimited.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>You have two ways to manage pairs: the graphical <a href="/setupg-guide/">SetupG</a> utility and the <a href="/setupc-commands/">setupc.exe command prompt</a>. Both change the same settings; use whichever you prefer.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Method 1: Create a pair in SetupG</h2>
<!-- /wp:heading -->

<!-- wp:list {"ordered":true} -->
<ol class="wp-block-list"><!-- wp:list-item -->
<li>Open <strong>SetupG</strong> from the com0com folder in your Start menu, with administrator rights. You will see the existing pairs listed — at minimum the default CNCA0 ↔ CNCB0 pair from installation.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Click <strong>Add Pair</strong>. A new pair appears with the next free default names (for example CNCA1 and CNCB1).</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Before you finish, consider renaming the new ports right away (next section). Default names work, but many applications cannot see them.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Apply the changes. Close any application that currently has one of the affected ports open first — a port in use cannot be reconfigured cleanly.</li>
<!-- /wp:list-item --></ol>

<!-- wp:heading -->
<h2 class="wp-block-heading">Method 2: Create a pair with setupc</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Open the Setup Command Prompt (setupc.exe) from the com0com installation folder, as administrator. The command to add a pair with default names is:</p>
<!-- /wp:paragraph -->

<!-- wp:code -->
<pre class="wp-block-code"><code>command&gt; install - -</code></pre>
<!-- /wp:code -->

<!-- wp:paragraph -->
<p>Each <code>-</code> tells setupc to assign the next default name for that end of the pair, which is why the result is a CNCA<em>n</em>/CNCB<em>n</em> pair. Run <code>list</code> afterwards to see every pair and port the driver currently has, and to confirm the new pair was added with the names you expected.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Rename the pair while you are at it</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Here is the step beginners skip and then lose an hour to: a large share of serial applications only enumerate ports with standard <strong>COM</strong> names. They will never offer CNCA0 in their port dropdown, no matter how correctly the driver is installed. The fix takes ten seconds. In SetupG, select the port and change its name using the <code>PortName=COM#</code> form — for example, turn CNCA0 into COM10 and CNCB0 into COM11. Assigning a name in that form also places the port in the Windows <strong>Ports class</strong>, so it appears in Device Manager alongside physical COM ports and becomes visible to applications that scan that class.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The same change from setupc looks like this:</p>
<!-- /wp:paragraph -->

<!-- wp:code -->
<pre class="wp-block-code"><code>command&gt; change CNCA0 PortName=COM10
command&gt; change CNCB0 PortName=COM11</code></pre>
<!-- /wp:code -->

<!-- wp:paragraph -->
<p>Pick numbers that are not already in use by physical hardware, Bluetooth serial links, or USB adapters, and avoid COM1 and COM2, which legacy software often assumes are motherboard ports. The full renaming guide — including what to do when the number you want seems taken — is <a href="/rename-com0com-port/">here</a>.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Prove it works: the two-window loopback test</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Before connecting any real software, verify the pair with the simplest test there is. You need any terminal program — PuTTY, Tera Term, or the terminal built into your development tools all work.</p>
<!-- /wp:paragraph -->

<!-- wp:list {"ordered":true} -->
<ol class="wp-block-list"><!-- wp:list-item -->
<li>Open the terminal and connect it to the <strong>first</strong> end of the pair (say COM10), using any settings — 9600 baud, 8 data bits, no parity, 1 stop bit is a fine starting point.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Open a <strong>second</strong> terminal window and connect it to the <strong>other</strong> end (COM11), with the same settings.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Type in the first window. Every character should appear in the second window — and nothing should appear in the window you typed in (unless your terminal has local echo switched on).</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Type back from the second window to the first. If both directions work, your pair is fully functional.</li>
<!-- /wp:list-item --></ol>

<!-- wp:paragraph -->
<p>If nothing arrives, check the basics before suspecting the driver: both windows must be connected to opposite ends of the <em>same</em> pair, no other program may hold either port open, and if you are using the CNCA/CNCB names, make sure your terminal can actually open them (the rename above solves this in most cases). More answers are in the <a href="/faq/">FAQ</a>.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">About baud rate, data bits and parity on a virtual pair</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>New users are often surprised that a virtual pair seems to ignore its speed setting. That is by design. With a physical cable, the baud rate is a real electrical signalling speed. With com0com, data moves through memory, so by default it is transferred as fast as the applications can handle, regardless of the baud rate the application selected — <strong>baud rate emulation (EmuBR) is off by default</strong>. The data bits, parity and stop-bit settings your application chooses are accepted, but there is no UART hardware enforcing them.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>Most of the time this instant, pass-through behaviour is exactly what you want — it is why virtual pairs are ideal for application-to-application links and for testing serial software. If you are developing software that must behave correctly at a real 9600 baud — for example, code that times out too aggressively when data arrives instantly — enable baud rate emulation for the sending port (in SetupG, or with <code>change CNCA0 EmuBR=yes</code> in setupc) and the driver will pace the data realistically. The <a href="/setupg-guide/">SetupG guide</a> covers EmuBR and its sibling options, overrun and noise emulation, in detail.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">One pair or many? Planning a small test bench</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>A single pair covers the classic case — one simulator talking to one application. Real test benches grow quickly, though: the application under test on one pair, a monitoring or logging setup watching a second scenario on another, a spare pair for the next experiment. Since pairs cost nothing and the driver supports an effectively unlimited number of them, create pairs per purpose rather than constantly reconfiguring one shared pair. Give each pair&#8217;s ends distinct COM names in a pattern (COM10/COM11 for the first setup, COM12/COM13 for the second) and jot down which pair serves which purpose. When a test misbehaves, that tiny bit of bookkeeping tells you instantly whether you are even looking at the right connection — a surprisingly common source of &#8220;com0com drops my data&#8221; reports that turn out to be two programs attached to different pairs.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>That is all a pair is: create it, give it real COM names, test it with two windows. From here the interesting part is what you connect to the ends — two of your own programs, a simulator and the software under test, or one end of a hub4com sharing setup. When you are ready to go further, the <a href="/guides/">Guides archive</a> collects every walkthrough on this site, and the <a href="/download/">download page</a> has the packages, including hub4com.</p>
<!-- /wp:paragraph -->
<!-- /wp:post-content -->]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/create-virtual-com-port-pair/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>How to Install com0com on Windows 11 — The Honest Guide</title>
		<link>https://com0com.com/install-com0com-windows-11/</link>
					<comments>https://com0com.com/install-com0com-windows-11/#respond</comments>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 01:00:00 +0000</pubDate>
				<category><![CDATA[Guides]]></category>
		<guid isPermaLink="false">https://com0com.com/?p=545</guid>

					<description><![CDATA[Installing com0com on Windows 11 is straightforward on many PCs — and genuinely frustrating on others. The difference is not the installer, it is your machine&#8217;s driver-signing policy. This guide walks you through the standard installation with the official signed package, explains exactly what you should see when it works, and is honest about the...]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Installing com0com on Windows 11 is straightforward on many PCs — and genuinely frustrating on others. The difference is not the installer, it is your machine&#8217;s driver-signing policy. This guide walks you through the standard installation with the official signed package, explains exactly what you should see when it works, and is honest about the one error you may hit instead: Code 52. No patched builds, no registry tricks, no promises nobody can keep.</p>



<p class="wp-block-paragraph">com0com (the Null-modem emulator) is a kernel-mode virtual serial port driver written by Vyacheslav Frolov and released under the GPLv2. It creates virtual COM port pairs: two virtual ports wired together in software, so one application can talk to another as if they were connected by a null-modem cable. The current version, 3.0.0.0, dates from 2012. That age is the root of every installation quirk described below.</p>



<h2 class="wp-block-heading">Before you start</h2>



<ul class="wp-block-list">
<li>You need an administrator account. Installing a kernel-mode driver always requires elevation.</li>



<li>Download only the official package from SourceForge. Our <a href="/download/">download page</a> links to it directly and publishes the SHA-256 checksum so you can verify the file yourself.</li>



<li>Know which Windows you have. com0com ships as separate 32-bit (x86) and 64-bit (x64) installers. Nearly every Windows 11 PC is 64-bit, and the package only exists for i386 and x64 — there is no ARM64 build.</li>



<li>Expect one of two outcomes: a clean install, or a Code 52 signature error. Both are normal for this driver in 2026, and this guide covers both.</li>
</ul>



<h2 class="wp-block-heading">Step 1: Download and verify the signed package</h2>



<p class="wp-block-paragraph">The file you want is <strong>com0com-3.0.0.0-i386-and-x64-signed.zip</strong> (475,063 bytes), uploaded to SourceForge on 2017-07-13. Despite the &#8220;signed&#8221; name and the 2017 upload date, the driver inside is the same 3.0.0.0 released in 2012 — the later upload simply added installers signed with a legacy cross-signing certificate (publisher: CyberCircuits). That distinction matters later in this guide.</p>



<p class="wp-block-paragraph">After downloading, verify the file before you install anything. Open PowerShell in your Downloads folder and run:</p>



<pre class="wp-block-code"><code>Get-FileHash .\com0com-3.0.0.0-i386-and-x64-signed.zip</code></pre>



<p class="wp-block-paragraph">The SHA-256 result should be <code>6e5d4359865277430d4ae88c73fb7e648a0ed8e81aea5002478179cfcb0bb0e1</code>. If it differs, delete the file and download it again from SourceForge — do not install a kernel driver whose hash does not match. This one habit protects you from the many repacked and &#8220;patched&#8221; copies floating around download sites.</p>



<h2 class="wp-block-heading">Step 2: Pick the right installer (ignore the &#8220;W7&#8221; in the name)</h2>



<p class="wp-block-paragraph">Extract the zip. Inside you will find two installers:</p>



<ul class="wp-block-list">
<li><strong>Setup_com0com_v3.0.0.0_W7_x64_signed.exe</strong> — for 64-bit Windows. This is the one almost every Windows 11 user needs.</li>



<li><strong>Setup_com0com_v3.0.0.0_W7_x86_signed.exe</strong> — for 32-bit Windows.</li>
</ul>



<p class="wp-block-paragraph">The <strong>W7</strong> in those filenames is historical: the installers were packaged in the Windows 7 era, when this signing was arranged. There is no separate &#8220;Windows 11 edition&#8221; of com0com, and version 3.0.0.0 is the newest release that exists — our <a href="/com0com-version-history/">version history</a> explains the full timeline. The W7 x64 installer is the correct and current official installer for Windows 11.</p>



<h2 class="wp-block-heading">Step 3: Run the installer as administrator</h2>



<p class="wp-block-paragraph">Right-click the x64 installer and choose <strong>Run as administrator</strong>, then work through the setup wizard. During installation Windows may show a security prompt asking whether you want to install device software from <strong>CyberCircuits</strong>. That is the expected publisher for this package: the installers carry a legacy cross-signed certificate issued to CyberCircuits, which is how a 2012 open-source driver was made installable on 64-bit Windows at all. It is not a Microsoft WHQL signature, and Windows 11 treats it accordingly — which is why the next step matters.</p>



<p class="wp-block-paragraph">Approve the prompt and let the wizard finish. The installer also sets up two companion tools you will use afterwards: <a href="/setupg-guide/">SetupG</a>, the graphical setup utility, and <a href="/setupc-commands/">setupc.exe</a>, its command-line equivalent.</p>



<h2 class="wp-block-heading">Step 4: Check the result in Device Manager</h2>



<p class="wp-block-paragraph">Open Device Manager (right-click the Start button) and look for the com0com devices. A successful installation shows the com0com serial port emulator and its first virtual port pair, <strong>CNCA0</strong> and <strong>CNCB0</strong>, with no warning icons. Windows creates that first pair automatically during setup.</p>



<p class="wp-block-paragraph">If instead you see a yellow warning icon and, in the device&#8217;s properties, the message <em>&#8220;Windows cannot verify the digital signature for the drivers required for this device. (Code 52)&#8221;</em>, the driver files were copied but Windows refused to load them. The installation did not fail because you did something wrong — read the next section before reinstalling or downloading anything else.</p>



<h2 class="wp-block-heading">If you get Code 52: what it means, and your two honest options</h2>



<p class="wp-block-paragraph">Code 52 is a signature-policy rejection. com0com&#8217;s driver is <em>test-signed</em>, and the signed package relies on a legacy cross-signing certificate from before Microsoft&#8217;s 2015-07-29 policy change. Since Windows 10 version 1607, fresh Windows installations normally only load kernel drivers signed through Microsoft&#8217;s Dev Portal. Older cross-signed drivers still load in some situations — depending on the certificate&#8217;s age, whether the PC was upgraded from an older Windows, and whether Secure Boot and Memory Integrity (HVCI) are enabled. That is why the same package installs cleanly on one Windows 11 PC and returns Code 52 on another. Anyone who promises you it &#8220;just works on Windows 11, no Test Mode, Secure Boot on&#8221; is describing their machine, not yours.</p>



<p class="wp-block-paragraph">Your options, in order:</p>



<ol class="wp-block-list">
<li><strong>Try the signed package first.</strong> If you installed the unsigned package by mistake, remove it and install the signed one — a large share of Code 52 reports turn out to be the unsigned build. The unsigned package&#8217;s x64 driver will never load with test signing off.</li>



<li><strong>Enable Test Mode.</strong> This is the project&#8217;s own documented route: the official ReadMe instructs users to run <code>bcdedit -set TESTSIGNING ON</code> and reboot so Windows will load the test-signed driver. The full step-by-step, including the security warning from that same ReadMe (test signing does weaken your system&#8217;s defences) and how to turn it back off, is on our <a href="/download/">download page</a>. One important caveat: on many PCs with Secure Boot enabled, Windows will refuse to change the test-signing setting at all — Secure Boot policy protects it. If you hit that, your choices are to disable Secure Boot in your UEFI settings (your decision, with its own trade-offs) or to accept that com0com cannot load on that machine as-is.</li>



<li><strong>On a locked-down machine, use a commercially signed alternative.</strong> If the PC is managed by an employer or must keep Secure Boot and HVCI fully enforced, no free build of com0com will load. That is the situation the paid, Microsoft-signed tools exist for; the <a href="/virtual-serial-port/">virtual serial port guide</a> compares them honestly, prices included.</li>
</ol>


<h2 class="wp-block-heading">What to do next</h2>



<p class="wp-block-paragraph">With the driver loaded, create your first pair and test it end-to-end — our walkthrough <a href="/create-virtual-com-port-pair/">Create Your First Virtual COM Port Pair</a> takes you from the default pair to a working loopback test in a few minutes. If your applications cannot see ports named CNCA0 and CNCB0, that is expected: many programs only list standard COM names, and <a href="/rename-com0com-port/">renaming a com0com port to a regular COM number</a> fixes it. Windows 10 users get the same driver with slightly different signing behaviour — see <a href="/com0com-windows-10/">com0com on Windows 10</a>. Anything else, from Test Mode watermarks to uninstalling cleanly, is answered in the <a href="/faq/">FAQ</a>.</p>



<p class="wp-block-paragraph">One last warning, because it matters for a kernel driver: this site previously saw third-party &#8220;2026 patch&#8221; builds of com0com advertised elsewhere. There is no 2026 version, and a modified kernel driver from an unverifiable source is a real security risk. Stick to the SourceForge package, check the hash, and use Test Mode openly if your machine needs it — that combination is the honest way to run com0com on Windows 11.</p>

]]></content:encoded>
					
					<wfw:commentRss>https://com0com.com/install-com0com-windows-11/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
